Revision tags: v6.15, v6.15-rc7, v6.15-rc6, v6.15-rc5, v6.15-rc4, v6.15-rc3, v6.15-rc2, v6.15-rc1, v6.14, v6.14-rc7, v6.14-rc6, v6.14-rc5, v6.14-rc4, v6.14-rc3, v6.14-rc2, v6.14-rc1, v6.13, v6.13-rc7, v6.13-rc6, v6.13-rc5, v6.13-rc4, v6.13-rc3, v6.13-rc2, v6.13-rc1, v6.12, v6.12-rc7, v6.12-rc6, v6.12-rc5, v6.12-rc4, v6.12-rc3, v6.12-rc2, v6.12-rc1, v6.11, v6.11-rc7, v6.11-rc6, v6.11-rc5, v6.11-rc4, v6.11-rc3, v6.11-rc2, v6.11-rc1, v6.10, v6.10-rc7, v6.10-rc6, v6.10-rc5, v6.10-rc4, v6.10-rc3, v6.10-rc2, v6.10-rc1, v6.9, v6.9-rc7, v6.9-rc6, v6.9-rc5, v6.9-rc4, v6.9-rc3, v6.9-rc2, v6.9-rc1, v6.8, v6.8-rc7, v6.8-rc6, v6.8-rc5, v6.8-rc4, v6.8-rc3, v6.8-rc2, v6.8-rc1 |
| #
8b1d7239 |
| 20-Jan-2024 |
Helge Deller <[email protected]> |
parisc: Fix random data corruption from exception handler
The current exception handler implementation, which assists when accessing user space memory, may exhibit random data corruption if the comp
parisc: Fix random data corruption from exception handler
The current exception handler implementation, which assists when accessing user space memory, may exhibit random data corruption if the compiler decides to use a different register than the specified register %r29 (defined in ASM_EXCEPTIONTABLE_REG) for the error code. If the compiler choose another register, the fault handler will nevertheless store -EFAULT into %r29 and thus trash whatever this register is used for. Looking at the assembly I found that this happens sometimes in emulate_ldd().
To solve the issue, the easiest solution would be if it somehow is possible to tell the fault handler which register is used to hold the error code. Using %0 or %1 in the inline assembly is not posssible as it will show up as e.g. %r29 (with the "%r" prefix), which the GNU assembler can not convert to an integer.
This patch takes another, better and more flexible approach: We extend the __ex_table (which is out of the execution path) by one 32-word. In this word we tell the compiler to insert the assembler instruction "or %r0,%r0,%reg", where %reg references the register which the compiler choosed for the error return code. In case of an access failure, the fault handler finds the __ex_table entry and can examine the opcode. The used register is encoded in the lowest 5 bits, and the fault handler can then store -EFAULT into this register.
Since we extend the __ex_table to 3 words we can't use the BUILDTIME_TABLE_SORT config option any longer.
Signed-off-by: Helge Deller <[email protected]> Cc: <[email protected]> # v6.0+
show more ...
|