1 #ifndef __NET_SCHED_CODEL_H 2 #define __NET_SCHED_CODEL_H 3 4 /* 5 * Codel - The Controlled-Delay Active Queue Management algorithm 6 * 7 * Copyright (C) 2011-2012 Kathleen Nichols <[email protected]> 8 * Copyright (C) 2011-2012 Van Jacobson <[email protected]> 9 * Copyright (C) 2012 Michael D. Taht <[email protected]> 10 * Copyright (C) 2012,2015 Eric Dumazet <[email protected]> 11 * 12 * Redistribution and use in source and binary forms, with or without 13 * modification, are permitted provided that the following conditions 14 * are met: 15 * 1. Redistributions of source code must retain the above copyright 16 * notice, this list of conditions, and the following disclaimer, 17 * without modification. 18 * 2. Redistributions in binary form must reproduce the above copyright 19 * notice, this list of conditions and the following disclaimer in the 20 * documentation and/or other materials provided with the distribution. 21 * 3. The names of the authors may not be used to endorse or promote products 22 * derived from this software without specific prior written permission. 23 * 24 * Alternatively, provided that this notice is retained in full, this 25 * software may be distributed under the terms of the GNU General 26 * Public License ("GPL") version 2, in which case the provisions of the 27 * GPL apply INSTEAD OF those given above. 28 * 29 * THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS 30 * "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT 31 * LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR 32 * A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT 33 * OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, 34 * SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT 35 * LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, 36 * DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY 37 * THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT 38 * (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE 39 * OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH 40 * DAMAGE. 41 * 42 */ 43 44 #include <linux/types.h> 45 #include <linux/ktime.h> 46 #include <linux/skbuff.h> 47 #include <net/pkt_sched.h> 48 #include <net/inet_ecn.h> 49 50 /* Controlling Queue Delay (CoDel) algorithm 51 * ========================================= 52 * Source : Kathleen Nichols and Van Jacobson 53 * http://queue.acm.org/detail.cfm?id=2209336 54 * 55 * Implemented on linux by Dave Taht and Eric Dumazet 56 */ 57 58 59 /* CoDel uses a 1024 nsec clock, encoded in u32 60 * This gives a range of 2199 seconds, because of signed compares 61 */ 62 typedef u32 codel_time_t; 63 typedef s32 codel_tdiff_t; 64 #define CODEL_SHIFT 10 65 #define MS2TIME(a) ((a * NSEC_PER_MSEC) >> CODEL_SHIFT) 66 67 static inline codel_time_t codel_get_time(void) 68 { 69 u64 ns = ktime_get_ns(); 70 71 return ns >> CODEL_SHIFT; 72 } 73 74 /* Dealing with timer wrapping, according to RFC 1982, as desc in wikipedia: 75 * https://en.wikipedia.org/wiki/Serial_number_arithmetic#General_Solution 76 * codel_time_after(a,b) returns true if the time a is after time b. 77 */ 78 #define codel_time_after(a, b) \ 79 (typecheck(codel_time_t, a) && \ 80 typecheck(codel_time_t, b) && \ 81 ((s32)((a) - (b)) > 0)) 82 #define codel_time_before(a, b) codel_time_after(b, a) 83 84 #define codel_time_after_eq(a, b) \ 85 (typecheck(codel_time_t, a) && \ 86 typecheck(codel_time_t, b) && \ 87 ((s32)((a) - (b)) >= 0)) 88 #define codel_time_before_eq(a, b) codel_time_after_eq(b, a) 89 90 /* Qdiscs using codel plugin must use codel_skb_cb in their own cb[] */ 91 struct codel_skb_cb { 92 codel_time_t enqueue_time; 93 }; 94 95 static struct codel_skb_cb *get_codel_cb(const struct sk_buff *skb) 96 { 97 qdisc_cb_private_validate(skb, sizeof(struct codel_skb_cb)); 98 return (struct codel_skb_cb *)qdisc_skb_cb(skb)->data; 99 } 100 101 static codel_time_t codel_get_enqueue_time(const struct sk_buff *skb) 102 { 103 return get_codel_cb(skb)->enqueue_time; 104 } 105 106 static void codel_set_enqueue_time(struct sk_buff *skb) 107 { 108 get_codel_cb(skb)->enqueue_time = codel_get_time(); 109 } 110 111 static inline u32 codel_time_to_us(codel_time_t val) 112 { 113 u64 valns = ((u64)val << CODEL_SHIFT); 114 115 do_div(valns, NSEC_PER_USEC); 116 return (u32)valns; 117 } 118 119 /** 120 * struct codel_params - contains codel parameters 121 * @target: target queue size (in time units) 122 * @ce_threshold: threshold for marking packets with ECN CE 123 * @interval: width of moving time window 124 * @mtu: device mtu, or minimal queue backlog in bytes. 125 * @ecn: is Explicit Congestion Notification enabled 126 */ 127 struct codel_params { 128 codel_time_t target; 129 codel_time_t ce_threshold; 130 codel_time_t interval; 131 u32 mtu; 132 bool ecn; 133 }; 134 135 /** 136 * struct codel_vars - contains codel variables 137 * @count: how many drops we've done since the last time we 138 * entered dropping state 139 * @lastcount: count at entry to dropping state 140 * @dropping: set to true if in dropping state 141 * @rec_inv_sqrt: reciprocal value of sqrt(count) >> 1 142 * @first_above_time: when we went (or will go) continuously above target 143 * for interval 144 * @drop_next: time to drop next packet, or when we dropped last 145 * @ldelay: sojourn time of last dequeued packet 146 */ 147 struct codel_vars { 148 u32 count; 149 u32 lastcount; 150 bool dropping; 151 u16 rec_inv_sqrt; 152 codel_time_t first_above_time; 153 codel_time_t drop_next; 154 codel_time_t ldelay; 155 }; 156 157 #define REC_INV_SQRT_BITS (8 * sizeof(u16)) /* or sizeof_in_bits(rec_inv_sqrt) */ 158 /* needed shift to get a Q0.32 number from rec_inv_sqrt */ 159 #define REC_INV_SQRT_SHIFT (32 - REC_INV_SQRT_BITS) 160 161 /** 162 * struct codel_stats - contains codel shared variables and stats 163 * @maxpacket: largest packet we've seen so far 164 * @drop_count: temp count of dropped packets in dequeue() 165 * @drop_len: bytes of dropped packets in dequeue() 166 * ecn_mark: number of packets we ECN marked instead of dropping 167 * ce_mark: number of packets CE marked because sojourn time was above ce_threshold 168 */ 169 struct codel_stats { 170 u32 maxpacket; 171 u32 drop_count; 172 u32 drop_len; 173 u32 ecn_mark; 174 u32 ce_mark; 175 }; 176 177 #define CODEL_DISABLED_THRESHOLD INT_MAX 178 179 static void codel_params_init(struct codel_params *params) 180 { 181 params->interval = MS2TIME(100); 182 params->target = MS2TIME(5); 183 params->ce_threshold = CODEL_DISABLED_THRESHOLD; 184 params->ecn = false; 185 } 186 187 static void codel_vars_init(struct codel_vars *vars) 188 { 189 memset(vars, 0, sizeof(*vars)); 190 } 191 192 static void codel_stats_init(struct codel_stats *stats) 193 { 194 stats->maxpacket = 0; 195 } 196 197 /* 198 * http://en.wikipedia.org/wiki/Methods_of_computing_square_roots#Iterative_methods_for_reciprocal_square_roots 199 * new_invsqrt = (invsqrt / 2) * (3 - count * invsqrt^2) 200 * 201 * Here, invsqrt is a fixed point number (< 1.0), 32bit mantissa, aka Q0.32 202 */ 203 static void codel_Newton_step(struct codel_vars *vars) 204 { 205 u32 invsqrt = ((u32)vars->rec_inv_sqrt) << REC_INV_SQRT_SHIFT; 206 u32 invsqrt2 = ((u64)invsqrt * invsqrt) >> 32; 207 u64 val = (3LL << 32) - ((u64)vars->count * invsqrt2); 208 209 val >>= 2; /* avoid overflow in following multiply */ 210 val = (val * invsqrt) >> (32 - 2 + 1); 211 212 vars->rec_inv_sqrt = val >> REC_INV_SQRT_SHIFT; 213 } 214 215 /* 216 * CoDel control_law is t + interval/sqrt(count) 217 * We maintain in rec_inv_sqrt the reciprocal value of sqrt(count) to avoid 218 * both sqrt() and divide operation. 219 */ 220 static codel_time_t codel_control_law(codel_time_t t, 221 codel_time_t interval, 222 u32 rec_inv_sqrt) 223 { 224 return t + reciprocal_scale(interval, rec_inv_sqrt << REC_INV_SQRT_SHIFT); 225 } 226 227 typedef u32 (*codel_skb_len_t)(const struct sk_buff *skb); 228 typedef codel_time_t (*codel_skb_time_t)(const struct sk_buff *skb); 229 typedef void (*codel_skb_drop_t)(struct sk_buff *skb, void *ctx); 230 typedef struct sk_buff * (*codel_skb_dequeue_t)(struct codel_vars *vars, 231 void *ctx); 232 233 static bool codel_should_drop(const struct sk_buff *skb, 234 void *ctx, 235 struct codel_vars *vars, 236 struct codel_params *params, 237 struct codel_stats *stats, 238 codel_skb_len_t skb_len_func, 239 codel_skb_time_t skb_time_func, 240 u32 *backlog, 241 codel_time_t now) 242 { 243 bool ok_to_drop; 244 u32 skb_len; 245 246 if (!skb) { 247 vars->first_above_time = 0; 248 return false; 249 } 250 251 skb_len = skb_len_func(skb); 252 vars->ldelay = now - skb_time_func(skb); 253 254 if (unlikely(skb_len > stats->maxpacket)) 255 stats->maxpacket = skb_len; 256 257 if (codel_time_before(vars->ldelay, params->target) || 258 *backlog <= params->mtu) { 259 /* went below - stay below for at least interval */ 260 vars->first_above_time = 0; 261 return false; 262 } 263 ok_to_drop = false; 264 if (vars->first_above_time == 0) { 265 /* just went above from below. If we stay above 266 * for at least interval we'll say it's ok to drop 267 */ 268 vars->first_above_time = now + params->interval; 269 } else if (codel_time_after(now, vars->first_above_time)) { 270 ok_to_drop = true; 271 } 272 return ok_to_drop; 273 } 274 275 static struct sk_buff *codel_dequeue(void *ctx, 276 u32 *backlog, 277 struct codel_params *params, 278 struct codel_vars *vars, 279 struct codel_stats *stats, 280 codel_skb_len_t skb_len_func, 281 codel_skb_time_t skb_time_func, 282 codel_skb_drop_t drop_func, 283 codel_skb_dequeue_t dequeue_func) 284 { 285 struct sk_buff *skb = dequeue_func(vars, ctx); 286 codel_time_t now; 287 bool drop; 288 289 if (!skb) { 290 vars->dropping = false; 291 return skb; 292 } 293 now = codel_get_time(); 294 drop = codel_should_drop(skb, ctx, vars, params, stats, 295 skb_len_func, skb_time_func, backlog, now); 296 if (vars->dropping) { 297 if (!drop) { 298 /* sojourn time below target - leave dropping state */ 299 vars->dropping = false; 300 } else if (codel_time_after_eq(now, vars->drop_next)) { 301 /* It's time for the next drop. Drop the current 302 * packet and dequeue the next. The dequeue might 303 * take us out of dropping state. 304 * If not, schedule the next drop. 305 * A large backlog might result in drop rates so high 306 * that the next drop should happen now, 307 * hence the while loop. 308 */ 309 while (vars->dropping && 310 codel_time_after_eq(now, vars->drop_next)) { 311 vars->count++; /* dont care of possible wrap 312 * since there is no more divide 313 */ 314 codel_Newton_step(vars); 315 if (params->ecn && INET_ECN_set_ce(skb)) { 316 stats->ecn_mark++; 317 vars->drop_next = 318 codel_control_law(vars->drop_next, 319 params->interval, 320 vars->rec_inv_sqrt); 321 goto end; 322 } 323 stats->drop_len += skb_len_func(skb); 324 drop_func(skb, ctx); 325 stats->drop_count++; 326 skb = dequeue_func(vars, ctx); 327 if (!codel_should_drop(skb, ctx, 328 vars, params, stats, 329 skb_len_func, 330 skb_time_func, 331 backlog, now)) { 332 /* leave dropping state */ 333 vars->dropping = false; 334 } else { 335 /* and schedule the next drop */ 336 vars->drop_next = 337 codel_control_law(vars->drop_next, 338 params->interval, 339 vars->rec_inv_sqrt); 340 } 341 } 342 } 343 } else if (drop) { 344 u32 delta; 345 346 if (params->ecn && INET_ECN_set_ce(skb)) { 347 stats->ecn_mark++; 348 } else { 349 stats->drop_len += skb_len_func(skb); 350 drop_func(skb, ctx); 351 stats->drop_count++; 352 353 skb = dequeue_func(vars, ctx); 354 drop = codel_should_drop(skb, ctx, vars, params, 355 stats, skb_len_func, 356 skb_time_func, backlog, now); 357 } 358 vars->dropping = true; 359 /* if min went above target close to when we last went below it 360 * assume that the drop rate that controlled the queue on the 361 * last cycle is a good starting point to control it now. 362 */ 363 delta = vars->count - vars->lastcount; 364 if (delta > 1 && 365 codel_time_before(now - vars->drop_next, 366 16 * params->interval)) { 367 vars->count = delta; 368 /* we dont care if rec_inv_sqrt approximation 369 * is not very precise : 370 * Next Newton steps will correct it quadratically. 371 */ 372 codel_Newton_step(vars); 373 } else { 374 vars->count = 1; 375 vars->rec_inv_sqrt = ~0U >> REC_INV_SQRT_SHIFT; 376 } 377 vars->lastcount = vars->count; 378 vars->drop_next = codel_control_law(now, params->interval, 379 vars->rec_inv_sqrt); 380 } 381 end: 382 if (skb && codel_time_after(vars->ldelay, params->ce_threshold) && 383 INET_ECN_set_ce(skb)) 384 stats->ce_mark++; 385 return skb; 386 } 387 #endif 388