1*b58fa269SRob Herring // SPDX-License-Identifier: GPL-2.0 2*b58fa269SRob Herring #include <linux/cpu.h> 3*b58fa269SRob Herring #include <linux/kernel.h> 4*b58fa269SRob Herring #include <linux/of.h> 5*b58fa269SRob Herring 6*b58fa269SRob Herring /** 7*b58fa269SRob Herring * of_get_cpu_hwid - Get the hardware ID from a CPU device node 8*b58fa269SRob Herring * 9*b58fa269SRob Herring * @cpun: CPU number(logical index) for which device node is required 10*b58fa269SRob Herring * @thread: The local thread number to get the hardware ID for. 11*b58fa269SRob Herring * 12*b58fa269SRob Herring * Return: The hardware ID for the CPU node or ~0ULL if not found. 13*b58fa269SRob Herring */ 14*b58fa269SRob Herring u64 of_get_cpu_hwid(struct device_node *cpun, unsigned int thread) 15*b58fa269SRob Herring { 16*b58fa269SRob Herring const __be32 *cell; 17*b58fa269SRob Herring int ac, len; 18*b58fa269SRob Herring 19*b58fa269SRob Herring ac = of_n_addr_cells(cpun); 20*b58fa269SRob Herring cell = of_get_property(cpun, "reg", &len); 21*b58fa269SRob Herring if (!cell || !ac || ((sizeof(*cell) * ac * (thread + 1)) > len)) 22*b58fa269SRob Herring return ~0ULL; 23*b58fa269SRob Herring 24*b58fa269SRob Herring cell += ac * thread; 25*b58fa269SRob Herring return of_read_number(cell, ac); 26*b58fa269SRob Herring } 27*b58fa269SRob Herring 28*b58fa269SRob Herring /* 29*b58fa269SRob Herring * arch_match_cpu_phys_id - Match the given logical CPU and physical id 30*b58fa269SRob Herring * 31*b58fa269SRob Herring * @cpu: logical cpu index of a core/thread 32*b58fa269SRob Herring * @phys_id: physical identifier of a core/thread 33*b58fa269SRob Herring * 34*b58fa269SRob Herring * CPU logical to physical index mapping is architecture specific. 35*b58fa269SRob Herring * However this __weak function provides a default match of physical 36*b58fa269SRob Herring * id to logical cpu index. phys_id provided here is usually values read 37*b58fa269SRob Herring * from the device tree which must match the hardware internal registers. 38*b58fa269SRob Herring * 39*b58fa269SRob Herring * Returns true if the physical identifier and the logical cpu index 40*b58fa269SRob Herring * correspond to the same core/thread, false otherwise. 41*b58fa269SRob Herring */ 42*b58fa269SRob Herring bool __weak arch_match_cpu_phys_id(int cpu, u64 phys_id) 43*b58fa269SRob Herring { 44*b58fa269SRob Herring return (u32)phys_id == cpu; 45*b58fa269SRob Herring } 46*b58fa269SRob Herring 47*b58fa269SRob Herring /* 48*b58fa269SRob Herring * Checks if the given "prop_name" property holds the physical id of the 49*b58fa269SRob Herring * core/thread corresponding to the logical cpu 'cpu'. If 'thread' is not 50*b58fa269SRob Herring * NULL, local thread number within the core is returned in it. 51*b58fa269SRob Herring */ 52*b58fa269SRob Herring static bool __of_find_n_match_cpu_property(struct device_node *cpun, 53*b58fa269SRob Herring const char *prop_name, int cpu, unsigned int *thread) 54*b58fa269SRob Herring { 55*b58fa269SRob Herring const __be32 *cell; 56*b58fa269SRob Herring int ac, prop_len, tid; 57*b58fa269SRob Herring u64 hwid; 58*b58fa269SRob Herring 59*b58fa269SRob Herring ac = of_n_addr_cells(cpun); 60*b58fa269SRob Herring cell = of_get_property(cpun, prop_name, &prop_len); 61*b58fa269SRob Herring if (!cell && !ac && arch_match_cpu_phys_id(cpu, 0)) 62*b58fa269SRob Herring return true; 63*b58fa269SRob Herring if (!cell || !ac) 64*b58fa269SRob Herring return false; 65*b58fa269SRob Herring prop_len /= sizeof(*cell) * ac; 66*b58fa269SRob Herring for (tid = 0; tid < prop_len; tid++) { 67*b58fa269SRob Herring hwid = of_read_number(cell, ac); 68*b58fa269SRob Herring if (arch_match_cpu_phys_id(cpu, hwid)) { 69*b58fa269SRob Herring if (thread) 70*b58fa269SRob Herring *thread = tid; 71*b58fa269SRob Herring return true; 72*b58fa269SRob Herring } 73*b58fa269SRob Herring cell += ac; 74*b58fa269SRob Herring } 75*b58fa269SRob Herring return false; 76*b58fa269SRob Herring } 77*b58fa269SRob Herring 78*b58fa269SRob Herring /* 79*b58fa269SRob Herring * arch_find_n_match_cpu_physical_id - See if the given device node is 80*b58fa269SRob Herring * for the cpu corresponding to logical cpu 'cpu'. Return true if so, 81*b58fa269SRob Herring * else false. If 'thread' is non-NULL, the local thread number within the 82*b58fa269SRob Herring * core is returned in it. 83*b58fa269SRob Herring */ 84*b58fa269SRob Herring bool __weak arch_find_n_match_cpu_physical_id(struct device_node *cpun, 85*b58fa269SRob Herring int cpu, unsigned int *thread) 86*b58fa269SRob Herring { 87*b58fa269SRob Herring /* Check for non-standard "ibm,ppc-interrupt-server#s" property 88*b58fa269SRob Herring * for thread ids on PowerPC. If it doesn't exist fallback to 89*b58fa269SRob Herring * standard "reg" property. 90*b58fa269SRob Herring */ 91*b58fa269SRob Herring if (IS_ENABLED(CONFIG_PPC) && 92*b58fa269SRob Herring __of_find_n_match_cpu_property(cpun, 93*b58fa269SRob Herring "ibm,ppc-interrupt-server#s", 94*b58fa269SRob Herring cpu, thread)) 95*b58fa269SRob Herring return true; 96*b58fa269SRob Herring 97*b58fa269SRob Herring return __of_find_n_match_cpu_property(cpun, "reg", cpu, thread); 98*b58fa269SRob Herring } 99*b58fa269SRob Herring 100*b58fa269SRob Herring /** 101*b58fa269SRob Herring * of_get_cpu_node - Get device node associated with the given logical CPU 102*b58fa269SRob Herring * 103*b58fa269SRob Herring * @cpu: CPU number(logical index) for which device node is required 104*b58fa269SRob Herring * @thread: if not NULL, local thread number within the physical core is 105*b58fa269SRob Herring * returned 106*b58fa269SRob Herring * 107*b58fa269SRob Herring * The main purpose of this function is to retrieve the device node for the 108*b58fa269SRob Herring * given logical CPU index. It should be used to initialize the of_node in 109*b58fa269SRob Herring * cpu device. Once of_node in cpu device is populated, all the further 110*b58fa269SRob Herring * references can use that instead. 111*b58fa269SRob Herring * 112*b58fa269SRob Herring * CPU logical to physical index mapping is architecture specific and is built 113*b58fa269SRob Herring * before booting secondary cores. This function uses arch_match_cpu_phys_id 114*b58fa269SRob Herring * which can be overridden by architecture specific implementation. 115*b58fa269SRob Herring * 116*b58fa269SRob Herring * Return: A node pointer for the logical cpu with refcount incremented, use 117*b58fa269SRob Herring * of_node_put() on it when done. Returns NULL if not found. 118*b58fa269SRob Herring */ 119*b58fa269SRob Herring struct device_node *of_get_cpu_node(int cpu, unsigned int *thread) 120*b58fa269SRob Herring { 121*b58fa269SRob Herring struct device_node *cpun; 122*b58fa269SRob Herring 123*b58fa269SRob Herring for_each_of_cpu_node(cpun) { 124*b58fa269SRob Herring if (arch_find_n_match_cpu_physical_id(cpun, cpu, thread)) 125*b58fa269SRob Herring return cpun; 126*b58fa269SRob Herring } 127*b58fa269SRob Herring return NULL; 128*b58fa269SRob Herring } 129*b58fa269SRob Herring EXPORT_SYMBOL(of_get_cpu_node); 130*b58fa269SRob Herring 131*b58fa269SRob Herring /** 132*b58fa269SRob Herring * of_cpu_device_node_get: Get the CPU device_node for a given logical CPU number 133*b58fa269SRob Herring * 134*b58fa269SRob Herring * @cpu: The logical CPU number 135*b58fa269SRob Herring * 136*b58fa269SRob Herring * Return: Pointer to the device_node for CPU with its reference count 137*b58fa269SRob Herring * incremented of the given logical CPU number or NULL if the CPU device_node 138*b58fa269SRob Herring * is not found. 139*b58fa269SRob Herring */ 140*b58fa269SRob Herring struct device_node *of_cpu_device_node_get(int cpu) 141*b58fa269SRob Herring { 142*b58fa269SRob Herring struct device *cpu_dev; 143*b58fa269SRob Herring cpu_dev = get_cpu_device(cpu); 144*b58fa269SRob Herring if (!cpu_dev) 145*b58fa269SRob Herring return of_get_cpu_node(cpu, NULL); 146*b58fa269SRob Herring return of_node_get(cpu_dev->of_node); 147*b58fa269SRob Herring } 148*b58fa269SRob Herring EXPORT_SYMBOL(of_cpu_device_node_get); 149*b58fa269SRob Herring 150*b58fa269SRob Herring /** 151*b58fa269SRob Herring * of_cpu_node_to_id: Get the logical CPU number for a given device_node 152*b58fa269SRob Herring * 153*b58fa269SRob Herring * @cpu_node: Pointer to the device_node for CPU. 154*b58fa269SRob Herring * 155*b58fa269SRob Herring * Return: The logical CPU number of the given CPU device_node or -ENODEV if the 156*b58fa269SRob Herring * CPU is not found. 157*b58fa269SRob Herring */ 158*b58fa269SRob Herring int of_cpu_node_to_id(struct device_node *cpu_node) 159*b58fa269SRob Herring { 160*b58fa269SRob Herring int cpu; 161*b58fa269SRob Herring bool found = false; 162*b58fa269SRob Herring struct device_node *np; 163*b58fa269SRob Herring 164*b58fa269SRob Herring for_each_possible_cpu(cpu) { 165*b58fa269SRob Herring np = of_cpu_device_node_get(cpu); 166*b58fa269SRob Herring found = (cpu_node == np); 167*b58fa269SRob Herring of_node_put(np); 168*b58fa269SRob Herring if (found) 169*b58fa269SRob Herring return cpu; 170*b58fa269SRob Herring } 171*b58fa269SRob Herring 172*b58fa269SRob Herring return -ENODEV; 173*b58fa269SRob Herring } 174*b58fa269SRob Herring EXPORT_SYMBOL(of_cpu_node_to_id); 175*b58fa269SRob Herring 176*b58fa269SRob Herring /** 177*b58fa269SRob Herring * of_get_cpu_state_node - Get CPU's idle state node at the given index 178*b58fa269SRob Herring * 179*b58fa269SRob Herring * @cpu_node: The device node for the CPU 180*b58fa269SRob Herring * @index: The index in the list of the idle states 181*b58fa269SRob Herring * 182*b58fa269SRob Herring * Two generic methods can be used to describe a CPU's idle states, either via 183*b58fa269SRob Herring * a flattened description through the "cpu-idle-states" binding or via the 184*b58fa269SRob Herring * hierarchical layout, using the "power-domains" and the "domain-idle-states" 185*b58fa269SRob Herring * bindings. This function check for both and returns the idle state node for 186*b58fa269SRob Herring * the requested index. 187*b58fa269SRob Herring * 188*b58fa269SRob Herring * Return: An idle state node if found at @index. The refcount is incremented 189*b58fa269SRob Herring * for it, so call of_node_put() on it when done. Returns NULL if not found. 190*b58fa269SRob Herring */ 191*b58fa269SRob Herring struct device_node *of_get_cpu_state_node(struct device_node *cpu_node, 192*b58fa269SRob Herring int index) 193*b58fa269SRob Herring { 194*b58fa269SRob Herring struct of_phandle_args args; 195*b58fa269SRob Herring int err; 196*b58fa269SRob Herring 197*b58fa269SRob Herring err = of_parse_phandle_with_args(cpu_node, "power-domains", 198*b58fa269SRob Herring "#power-domain-cells", 0, &args); 199*b58fa269SRob Herring if (!err) { 200*b58fa269SRob Herring struct device_node *state_node = 201*b58fa269SRob Herring of_parse_phandle(args.np, "domain-idle-states", index); 202*b58fa269SRob Herring 203*b58fa269SRob Herring of_node_put(args.np); 204*b58fa269SRob Herring if (state_node) 205*b58fa269SRob Herring return state_node; 206*b58fa269SRob Herring } 207*b58fa269SRob Herring 208*b58fa269SRob Herring return of_parse_phandle(cpu_node, "cpu-idle-states", index); 209*b58fa269SRob Herring } 210*b58fa269SRob Herring EXPORT_SYMBOL(of_get_cpu_state_node); 211