Home
last modified time | relevance | path

Searched refs:measurements (Results 1 – 25 of 123) sorted by relevance

12345

/linux-6.15/Documentation/hwmon/
H A Dmp2856.rst49 The driver provides the following sysfs attributes for current measurements:
60 The driver provides the following sysfs attributes for voltage measurements.
77 The driver provides the following sysfs attributes for power measurements.
88 The driver provides the following sysfs attributes for temperature measurements.
H A Dltc2991.rst29 supply voltages and can be paired for differential measurements of current sense
30 resistors or temperature sensing transistors. Additional measurements include
H A Dnct7904.rst34 in[1-20]_input Input voltage measurements (mV)
36 fan[1-12]_input Fan tachometer measurements (rpm)
H A Dina3221.rst50 measurements, activates the corresponding alarm
55 current measurements.
H A Dbt1-pvt.rst35 the threshold status bits. Depending on the measurements timeout settings
64 provides a constant measurements discreteness. The data scaling is also
104 temperature measurements within 7.130
/linux-6.15/Documentation/devicetree/bindings/hwmon/
H A Dltc2990.txt11 addition the following input measurements are enabled per mode:
23 allows a subset of the measurements to be enabled:
28 3: All measurements per mode
H A Dbaikal,bt1-pvt.yaml22 measurements timeout. Its internal structure is depicted on the next
75 temperature measurements within 7.130 degrees Celsius.
H A Dmax31785.txt11 dual tachometer measurements, and fan health monitoring.
H A Dti,ina3221.yaml24 measurements). The continuous mode is more reliable and suitable for
27 consumptions while still needs some measurements occasionally.
/linux-6.15/Documentation/ABI/testing/
H A Dsysfs-bus-iio-sx93108 proximity measurements constructed by hardware by
9 combining measurements taken from a given set of
H A Dsysfs-driver-panthor-profiling6 Bitmask to enable drm fdinfo's job profiling measurements.
9 1: Enable GPU cycle measurements for running jobs.
H A Dsysfs-driver-genwqe50 Used for performance and utilization measurements.
56 Used for performance and utilization measurements.
H A Dsysfs-bus-iio-proximity18 on the signal from which time of flight measurements are
/linux-6.15/drivers/iio/health/
H A Dmax30102.c262 unsigned int measurements) in max30102_read_measurement() argument
269 measurements * in max30102_read_measurement()
273 switch (measurements) { in max30102_read_measurement()
287 return (ret == measurements * MAX30102_REG_FIFO_DATA_BYTES) ? in max30102_read_measurement()
295 unsigned int measurements = bitmap_weight(indio_dev->active_scan_mask, in max30102_interrupt_handler() local
302 ret = max30102_read_measurement(data, measurements); in max30102_interrupt_handler()
/linux-6.15/Documentation/devicetree/bindings/input/touchscreen/
H A Dadi,ad7879.yaml68 1: 4 measurements
69 2: 8 measurements
70 3: 16 measurements
/linux-6.15/Documentation/iio/
H A Dadis16475.rst28 measurements over a broad set of conditions.
33 Accelerometer, gyroscope measurements are always provided. Furthermore, the
35 measurements computed by the device.
37 The delta angle measurements represent a calculation of angular displacement
38 between each sample update, while the delta velocity measurements represent a
309 measurements using buffers.
312 angle and temperature measurements using buffers:
H A Dadis16480.rst30 accurate sensor measurements.
35 Accelerometer, gyroscope measurements are always provided. Furthermore, the
37 measurements computed by the device.
39 The delta angle measurements represent a calculation of angular displacement
40 between each sample update, while the delta velocity measurements represent a
48 triaxial magnetometer measurements.
372 measurements using buffers.
375 angle and temperature measurements using buffers:
H A Dadis16550.rst17 compensation formulas that provide accurate sensor measurements.
22 Accelerometer, gyroscope measurements are always provided. Furthermore, the
24 measurements computed by the device.
26 The delta angle measurements represent a calculation of angular displacement
27 between each sample update, while the delta velocity measurements represent a
306 delta angle and temperature measurements using buffers.
/linux-6.15/Documentation/userspace-api/media/dvb/
H A Dfrontend-stat-properties.rst108 bit count measurements. The frontend may reset it when a
136 bit count measurements. The frontend may reset it when a
165 bit count measurements. The frontend may reset it when a
193 bit count measurements. The frontend may reset it when a
214 bit count measurements. The frontend may reset it when a
H A Dfrontend_legacy_dvbv3_api.rst10 TV standards, doesn't provide good statistics measurements and provides
/linux-6.15/Documentation/devicetree/bindings/sound/
H A Dda7218.txt56 - dlg,jack-rate-us : Time between jack detect measurements (us)
58 - dlg,jack-debounce : Number of debounce measurements taken for jack detect
/linux-6.15/tools/perf/Documentation/
H A Dperf-stat.txt180 # Table of individual measurements:
232 disable events during measurements:
298 Aggregate counts per processor socket for system-wide mode measurements. This
305 Aggregate counts per processor die for system-wide mode measurements. This
320 Aggregate counts per cache instance for system-wide mode measurements. By
338 Aggregate counts per NUMA nodes for system-wide mode measurements. This
402 Aggregate counts per processor socket for system-wide mode measurements.
405 Aggregate counts per processor die for system-wide mode measurements.
408 Aggregate counts perf processor cluster for system-wide mode measurements.
411 Aggregate counts per cache instance for system-wide mode measurements. By
[all …]
/linux-6.15/Documentation/devicetree/bindings/iio/adc/
H A Dmediatek,mt6359-auxadc.yaml14 in some MediaTek PMICs, performing various PMIC related measurements
/linux-6.15/Documentation/devicetree/bindings/extcon/
H A Dwlf,arizona.yaml72 Delay between successive microphone detection measurements, specified
81 measurements to take.
/linux-6.15/Documentation/w1/slaves/
H A Dw1_ds2438.rst32 measurements.
33 Writing value "1" is setting the IAD bit (enables the measurements).

12345