Home
last modified time | relevance | path

Searched refs:Shutdown (Results 1 – 25 of 47) sorted by relevance

12

/linux-6.15/Documentation/devicetree/bindings/clock/
H A Didt,versaclock5.yaml34 SH (en_global_shutdown) and SP bits of the Primary Source and Shutdown
42 1 0 Active/Shutdown
43 1 1 Inactive/Shutdown
91 bit of the Primary Source and Shutdown Register.
101 Shutdown Register.
/linux-6.15/Documentation/devicetree/bindings/sound/
H A Dqcom,wsa8840.yaml28 description: Powerdown/Shutdown line to use (pin SD_N)
32 description: Powerdown/Shutdown line to use (pin SD_N)
H A Dqcom,wsa881x.yaml29 description: GPIO spec for Powerdown/Shutdown line to use
H A Dqcom,wsa883x.yaml29 description: GPIO spec for Powerdown/Shutdown line to use (pin SD_N)
/linux-6.15/Documentation/sound/soc/
H A Dpops-clicks.rst28 Shutdown Order :- Digital Mute --> Output PGA --> Mixers --> DAC
45 Shutdown Order - ADC --> Mixers --> Input PGA
/linux-6.15/Documentation/ABI/testing/
H A Dsysfs-driver-input-axp-pek10 Description: Shutdown time in us. Board is powered off if the button is pressed
H A Dsysfs-class-mic85 "crashed" Shutdown because of a HW or SW crash.
86 "halted" Shutdown because of a halt command.
87 "poweroff" Shutdown because of a poweroff command.
88 "restart" Shutdown because of a restart command.
/linux-6.15/Documentation/hwmon/
H A Dthmc50.rst47 sensors, limits can be set through the appropriate Overtemperature Shutdown
50 temperature gets higher then the Overtemperature Shutdown value; it stays on
H A Dtmp102.rst22 set through the Overtemperature Shutdown register and Hysteresis register. The
H A Dlm78.rst46 when the Overtemperature Shutdown limit is crossed; it is triggered again
50 is above the Overtemperature Shutdown value. Measurements are guaranteed
H A Dlm75.rst154 Overtemperature Shutdown register and Hysteresis register. Each value can be
157 gets higher then the Overtemperature Shutdown value; it stays on until
H A Dlm80.rst46 drops below the HOT Hysteresis. The Overtemperature Shutdown (OS) limits
H A Dvia686a.rst49 when the Overtemperature Shutdown limit is crossed; it is triggered again
H A Dabituguru-datasheet.rst245 - Volt sensor: Shutdown if alarm persist for more than 4 seconds (RW)
246 - Temp sensor: Shutdown if temp is over the shutdown threshold (RW)
320 Shutdown if alarm persist for more than 4 seconds (RW)
/linux-6.15/Documentation/driver-api/thermal/
H A Dnouveau_thermal.rst37 * Shutdown:
50 * Shutdown: temp1_emergency and temp1_emergency_hyst.
/linux-6.15/drivers/soc/loongson/
H A DKconfig27 Disk), ACPI S5 (Soft Shutdown) and supports multiple wake-up methods
/linux-6.15/Documentation/devicetree/bindings/power/reset/
H A Datmel,at91sam9260-shdwc.yaml7 title: Microchip AT91 SHDWC Shutdown Controller
H A Datmel,sama5d2-shdwc.yaml7 title: Microchip AT91 SAMA5D2 SHDWC Shutdown Controller
/linux-6.15/Documentation/devicetree/bindings/remoteproc/
H A Dqcom,pas-common.yaml35 - description: Shutdown acknowledge interrupt
H A Dqcom,sc7280-wpss-pil.yaml33 - description: Shutdown acknowledge interrupt
H A Dqcom,sc7280-adsp-pil.yaml37 - description: Shutdown acknowledge interrupt
/linux-6.15/arch/mips/include/asm/mach-loongson64/
H A Dboot_param.h184 u64 Shutdown; member
/linux-6.15/arch/mips/loongson64/
H A Denv.c169 loongson_sysconf.poweroff_addr = boot_p->reset_system.Shutdown; in prom_lefi_init_env()
/linux-6.15/Documentation/devicetree/bindings/iio/adc/
H A Dmaxim,max34408.yaml46 Shutdown Output. Open-drain output. This output transitions to high impedance
/linux-6.15/Documentation/devicetree/bindings/iio/dac/
H A Dadi,ad8460.yaml105 description: Corresponds to SDN_IO pin. Shutdown may be

12