Home
last modified time | relevance | path

Searched refs:domains (Results 1 – 25 of 385) sorted by relevance

12345678910>>...16

/f-stack/freebsd/contrib/device-tree/src/arm/
H A Dmt7623a.dtsi13 power-domains = <&scpsys MT7623A_POWER_DOMAIN_IFR_MSC>;
17 power-domains = <&scpsys MT7623A_POWER_DOMAIN_ETH>;
21 power-domains = <&scpsys MT7623A_POWER_DOMAIN_ETH>;
25 power-domains = <&scpsys MT7623A_POWER_DOMAIN_IFR_MSC>;
29 power-domains = <&scpsys MT7623A_POWER_DOMAIN_HIF>;
39 power-domains = <&scpsys MT7623A_POWER_DOMAIN_HIF>;
43 power-domains = <&scpsys MT7623A_POWER_DOMAIN_HIF>;
H A Dr8a77470.dtsi36 power-domains = <&sysc R8A77470_PD_CA7_CPU0>;
46 power-domains = <&sysc R8A77470_PD_CA7_CPU1>;
54 power-domains = <&sysc R8A77470_PD_CA7_SCU>;
94 power-domains = <&sysc R8A77470_PD_ALWAYS_ON>;
110 power-domains = <&sysc R8A77470_PD_ALWAYS_ON>;
125 power-domains = <&sysc R8A77470_PD_ALWAYS_ON>;
140 power-domains = <&sysc R8A77470_PD_ALWAYS_ON>;
156 power-domains = <&sysc R8A77470_PD_ALWAYS_ON>;
171 power-domains = <&sysc R8A77470_PD_ALWAYS_ON>;
186 power-domains = <&sysc R8A77470_PD_ALWAYS_ON>;
[all …]
H A Dr8a7792.dtsi56 power-domains = <&sysc R8A7792_PD_CA15_CPU0>;
66 power-domains = <&sysc R8A7792_PD_CA15_CPU1>;
74 power-domains = <&sysc R8A7792_PD_CA15_SCU>;
114 power-domains = <&sysc R8A7792_PD_ALWAYS_ON>;
130 power-domains = <&sysc R8A7792_PD_ALWAYS_ON>;
145 power-domains = <&sysc R8A7792_PD_ALWAYS_ON>;
160 power-domains = <&sysc R8A7792_PD_ALWAYS_ON>;
175 power-domains = <&sysc R8A7792_PD_ALWAYS_ON>;
190 power-domains = <&sysc R8A7792_PD_ALWAYS_ON>;
205 power-domains = <&sysc R8A7792_PD_ALWAYS_ON>;
[all …]
H A Dr7s9210.dtsi84 power-domains = <&cpg>;
101 power-domains = <&cpg>;
118 power-domains = <&cpg>;
135 power-domains = <&cpg>;
152 power-domains = <&cpg>;
164 power-domains = <&cpg>;
179 power-domains = <&cpg>;
194 power-domains = <&cpg>;
206 power-domains = <&cpg>;
219 power-domains = <&cpg>;
[all …]
H A Dkeystone-k2g.dtsi150 power-domains = <&k2g_pds 0x2c>;
162 power-domains = <&k2g_pds 0x2d>;
174 power-domains = <&k2g_pds 0x2e>;
340 power-domains = <&k2g_pds 0x2>;
365 power-domains = <&k2g_pds 0x3f>;
371 power-domains = <&k2g_pds 0x3f>;
422 power-domains = <&k2g_pds 0xb>;
436 power-domains = <&k2g_pds 0xc>;
466 power-domains = <&k2g_pds 0x4>;
482 power-domains = <&k2g_pds 0x5>;
[all …]
H A Dr8a7791.dtsi79 power-domains = <&sysc R8A7791_PD_CA15_CPU0>;
99 power-domains = <&sysc R8A7791_PD_CA15_CPU1>;
115 power-domains = <&sysc R8A7791_PD_CA15_SCU>;
164 power-domains = <&sysc R8A7791_PD_ALWAYS_ON>;
180 power-domains = <&sysc R8A7791_PD_ALWAYS_ON>;
195 power-domains = <&sysc R8A7791_PD_ALWAYS_ON>;
210 power-domains = <&sysc R8A7791_PD_ALWAYS_ON>;
225 power-domains = <&sysc R8A7791_PD_ALWAYS_ON>;
240 power-domains = <&sysc R8A7791_PD_ALWAYS_ON>;
255 power-domains = <&sysc R8A7791_PD_ALWAYS_ON>;
[all …]
H A Dr8a7790.dtsi80 power-domains = <&sysc R8A7790_PD_CA15_CPU0>;
101 power-domains = <&sysc R8A7790_PD_CA15_CPU1>;
122 power-domains = <&sysc R8A7790_PD_CA15_CPU2>;
143 power-domains = <&sysc R8A7790_PD_CA15_CPU3>;
164 power-domains = <&sysc R8A7790_PD_CA7_CPU0>;
175 power-domains = <&sysc R8A7790_PD_CA7_CPU1>;
186 power-domains = <&sysc R8A7790_PD_CA7_CPU2>;
197 power-domains = <&sysc R8A7790_PD_CA7_CPU3>;
204 power-domains = <&sysc R8A7790_PD_CA15_SCU>;
211 power-domains = <&sysc R8A7790_PD_CA7_SCU>;
[all …]
/f-stack/freebsd/contrib/device-tree/src/arm64/renesas/
H A Dr8a77980.dtsi44 power-domains = <&sysc R8A77980_PD_CA53_CPU0>;
54 power-domains = <&sysc R8A77980_PD_CA53_CPU1>;
64 power-domains = <&sysc R8A77980_PD_CA53_CPU2>;
74 power-domains = <&sysc R8A77980_PD_CA53_CPU3>;
81 power-domains = <&sysc R8A77980_PD_CA53_SCU>;
142 power-domains = <&sysc R8A77980_PD_ALWAYS_ON>;
158 power-domains = <&sysc R8A77980_PD_ALWAYS_ON>;
173 power-domains = <&sysc R8A77980_PD_ALWAYS_ON>;
188 power-domains = <&sysc R8A77980_PD_ALWAYS_ON>;
203 power-domains = <&sysc R8A77980_PD_ALWAYS_ON>;
[all …]
H A Dr8a77995.dtsi33 power-domains = <&sysc R8A77995_PD_CA53_CPU0>;
40 power-domains = <&sysc R8A77995_PD_CA53_SCU>;
81 power-domains = <&sysc R8A77995_PD_ALWAYS_ON>;
97 power-domains = <&sysc R8A77995_PD_ALWAYS_ON>;
112 power-domains = <&sysc R8A77995_PD_ALWAYS_ON>;
127 power-domains = <&sysc R8A77995_PD_ALWAYS_ON>;
142 power-domains = <&sysc R8A77995_PD_ALWAYS_ON>;
157 power-domains = <&sysc R8A77995_PD_ALWAYS_ON>;
172 power-domains = <&sysc R8A77995_PD_ALWAYS_ON>;
187 power-domains = <&sysc R8A77995_PD_ALWAYS_ON>;
[all …]
H A Dr8a77970.dtsi43 power-domains = <&sysc R8A77970_PD_CA53_CPU0>;
53 power-domains = <&sysc R8A77970_PD_CA53_CPU1>;
60 power-domains = <&sysc R8A77970_PD_CA53_SCU>;
112 power-domains = <&sysc R8A77970_PD_ALWAYS_ON>;
128 power-domains = <&sysc R8A77970_PD_ALWAYS_ON>;
143 power-domains = <&sysc R8A77970_PD_ALWAYS_ON>;
158 power-domains = <&sysc R8A77970_PD_ALWAYS_ON>;
173 power-domains = <&sysc R8A77970_PD_ALWAYS_ON>;
188 power-domains = <&sysc R8A77970_PD_ALWAYS_ON>;
203 power-domains = <&sysc R8A77970_PD_ALWAYS_ON>;
[all …]
H A Dr8a77951.dtsi155 power-domains = <&sysc R8A7795_PD_CA57_CPU0>;
170 power-domains = <&sysc R8A7795_PD_CA57_CPU1>;
184 power-domains = <&sysc R8A7795_PD_CA57_CPU2>;
264 power-domains = <&sysc R8A7795_PD_CA57_SCU>;
271 power-domains = <&sysc R8A7795_PD_CA53_SCU>;
1104 power-domains = <&sysc R8A7795_PD_A3IR>;
1169 power-domains = <&sysc R8A7795_PD_A3VC>;
1177 power-domains = <&sysc R8A7795_PD_A3VC>;
1201 power-domains = <&sysc R8A7795_PD_A3VP>;
1209 power-domains = <&sysc R8A7795_PD_A3VP>;
[all …]
H A Dr8a774c0.dtsi77 power-domains = <&sysc R8A774C0_PD_CA53_CPU0>;
89 power-domains = <&sysc R8A774C0_PD_CA53_CPU1>;
98 power-domains = <&sysc R8A774C0_PD_CA53_SCU>;
149 power-domains = <&sysc R8A774C0_PD_ALWAYS_ON>;
165 power-domains = <&sysc R8A774C0_PD_ALWAYS_ON>;
180 power-domains = <&sysc R8A774C0_PD_ALWAYS_ON>;
195 power-domains = <&sysc R8A774C0_PD_ALWAYS_ON>;
210 power-domains = <&sysc R8A774C0_PD_ALWAYS_ON>;
225 power-domains = <&sysc R8A774C0_PD_ALWAYS_ON>;
240 power-domains = <&sysc R8A774C0_PD_ALWAYS_ON>;
[all …]
H A Dr8a77990.dtsi88 power-domains = <&sysc R8A77990_PD_CA53_CPU0>;
101 power-domains = <&sysc R8A77990_PD_CA53_CPU1>;
111 power-domains = <&sysc R8A77990_PD_CA53_SCU>;
175 power-domains = <&sysc R8A77990_PD_ALWAYS_ON>;
191 power-domains = <&sysc R8A77990_PD_ALWAYS_ON>;
206 power-domains = <&sysc R8A77990_PD_ALWAYS_ON>;
221 power-domains = <&sysc R8A77990_PD_ALWAYS_ON>;
236 power-domains = <&sysc R8A77990_PD_ALWAYS_ON>;
251 power-domains = <&sysc R8A77990_PD_ALWAYS_ON>;
266 power-domains = <&sysc R8A77990_PD_ALWAYS_ON>;
[all …]
H A Dr8a774e1.dtsi127 power-domains = <&sysc R8A774E1_PD_CA57_CPU0>;
141 power-domains = <&sysc R8A774E1_PD_CA57_CPU1>;
154 power-domains = <&sysc R8A774E1_PD_CA57_CPU2>;
167 power-domains = <&sysc R8A774E1_PD_CA57_CPU3>;
180 power-domains = <&sysc R8A774E1_PD_CA53_CPU0>;
228 power-domains = <&sysc R8A774E1_PD_CA57_SCU>;
235 power-domains = <&sysc R8A774E1_PD_CA53_SCU>;
1058 power-domains = <&sysc R8A774E1_PD_A3VC>;
1066 power-domains = <&sysc R8A774E1_PD_A3VC>;
1090 power-domains = <&sysc R8A774E1_PD_A3VP>;
[all …]
H A Dr8a77961.dtsi149 power-domains = <&sysc R8A77961_PD_CA57_CPU0>;
164 power-domains = <&sysc R8A77961_PD_CA57_CPU1>;
178 power-domains = <&sysc R8A77961_PD_CA53_CPU0>;
193 power-domains = <&sysc R8A77961_PD_CA53_CPU1>;
206 power-domains = <&sysc R8A77961_PD_CA53_CPU2>;
219 power-domains = <&sysc R8A77961_PD_CA53_CPU3>;
230 power-domains = <&sysc R8A77961_PD_CA57_SCU>;
237 power-domains = <&sysc R8A77961_PD_CA53_SCU>;
326 power-domains = <&sysc R8A77961_PD_ALWAYS_ON>;
914 power-domains = <&sysc R8A77961_PD_A3IR>;
[all …]
H A Dr8a77960.dtsi160 power-domains = <&sysc R8A7796_PD_CA57_CPU0>;
175 power-domains = <&sysc R8A7796_PD_CA57_CPU1>;
241 power-domains = <&sysc R8A7796_PD_CA57_SCU>;
248 power-domains = <&sysc R8A7796_PD_CA53_SCU>;
1028 power-domains = <&sysc R8A7796_PD_A3IR>;
1077 power-domains = <&sysc R8A7796_PD_A3VC>;
2526 power-domains = <&sysc R8A7796_PD_A3VC>;
2536 power-domains = <&sysc R8A7796_PD_A3VC>;
2545 power-domains = <&sysc R8A7796_PD_A3VC>;
2554 power-domains = <&sysc R8A7796_PD_A3VC>;
[all …]
H A Dr8a774a1.dtsi137 power-domains = <&sysc R8A774A1_PD_CA57_CPU0>;
151 power-domains = <&sysc R8A774A1_PD_CA57_CPU1>;
164 power-domains = <&sysc R8A774A1_PD_CA53_CPU0>;
212 power-domains = <&sysc R8A774A1_PD_CA57_SCU>;
219 power-domains = <&sysc R8A774A1_PD_CA53_SCU>;
1066 power-domains = <&sysc R8A774A1_PD_A3VC>;
2379 power-domains = <&sysc R8A774A1_PD_A3VC>;
2388 power-domains = <&sysc R8A774A1_PD_A3VC>;
2396 power-domains = <&sysc R8A774A1_PD_A3VC>;
2431 power-domains = <&sysc R8A774A1_PD_A3VC>;
[all …]
H A Dr8a77965.dtsi111 power-domains = <&sysc R8A77965_PD_CA57_CPU0>;
125 power-domains = <&sysc R8A77965_PD_CA57_CPU1>;
135 power-domains = <&sysc R8A77965_PD_CA57_SCU>;
931 power-domains = <&sysc R8A77965_PD_A3VC>;
947 power-domains = <&sysc R8A77965_PD_A3VP>;
2262 power-domains = <&sysc R8A77965_PD_A3VP>;
2271 power-domains = <&sysc R8A77965_PD_A3VP>;
2280 power-domains = <&sysc R8A77965_PD_A3VP>;
2291 power-domains = <&sysc R8A77965_PD_A3VP>;
2323 power-domains = <&sysc R8A77965_PD_A3VP>;
[all …]
H A Dr8a774b1.dtsi80 power-domains = <&sysc R8A774B1_PD_CA57_CPU0>;
93 power-domains = <&sysc R8A774B1_PD_CA57_CPU1>;
102 power-domains = <&sysc R8A774B1_PD_CA57_SCU>;
932 power-domains = <&sysc R8A774B1_PD_A3VC>;
948 power-domains = <&sysc R8A774B1_PD_A3VP>;
2248 power-domains = <&sysc R8A774B1_PD_A3VP>;
2257 power-domains = <&sysc R8A774B1_PD_A3VP>;
2266 power-domains = <&sysc R8A774B1_PD_A3VP>;
2277 power-domains = <&sysc R8A774B1_PD_A3VP>;
2309 power-domains = <&sysc R8A774B1_PD_A3VP>;
[all …]
/f-stack/freebsd/contrib/device-tree/Bindings/power/
H A Dpower_domain.txt1 * Generic PM domains
3 System on chip designs are often divided into multiple PM domains that can be
8 their PM domains provided by PM domain providers. A PM domain provider can be
10 domains. A consumer node can refer to the provider by a phandle and a set of
26 order as the power-domains property. Consumers drivers will use
27 power-domain-names to match power domains with power-domains
35 power-domains = <&power 0>;
42 power-domains = <&power 0>, <&power 1> ;
63 - OPP table for domain provider that provides two domains.
101 power-domains = <&power 0>;
[all …]
H A Dpower-domain.yaml7 title: Generic PM domains
15 System on chip designs are often divided into multiple PM domains that can be
20 their PM domains provided by PM domain providers. A PM domain provider can be
22 domains. A consumer node can refer to the provider by a phandle and a set of
48 the power domains provided by the provider have identical OPP tables,
56 domains (e.g. power controllers), but can be any value as specified
59 power-domains:
62 controller specified by phandle. Some power domains might be powered
65 consumer binding is used. When provided, all domains created
93 power-domains = <&parent2 0>;
[all …]
/f-stack/freebsd/contrib/device-tree/Bindings/arm/ux500/
H A Dpower_domain.txt3 UX500 supports multiple PM domains which are used to gate power to one or
6 The implementation of PM domains for UX500 are based upon the generic PM domain
12 - compatible: Must be "stericsson,ux500-pm-domains".
17 compatible = "stericsson,ux500-pm-domains";
24 - power-domains: A phandle and PM domain specifier. Below are the list of
34 power-domains = <&pm_domains DOMAIN_VAPE>
/f-stack/freebsd/contrib/device-tree/Bindings/media/
H A Dqcom,sdm845-venus.yaml27 power-domains:
60 power-domains:
67 - power-domains
86 power-domains:
93 - power-domains
115 - power-domains
136 power-domains = <&videocc VENUS_GDSC>;
146 power-domains = <&videocc VCODEC0_GDSC>;
154 power-domains = <&videocc VCODEC1_GDSC>;
H A Dqcom,msm8996-venus.yaml27 power-domains:
60 power-domains:
67 - power-domains
85 power-domains:
92 - power-domains
114 - power-domains
136 power-domains = <&mmcc VENUS_GDSC>;
163 power-domains = <&mmcc VENUS_CORE0_GDSC>;
170 power-domains = <&mmcc VENUS_CORE1_GDSC>;
/f-stack/freebsd/contrib/device-tree/src/arm64/xilinx/
H A Dzynqmp.dtsi220 power-domains = <&zynqmp_firmware PD_CAN_0>;
232 power-domains = <&zynqmp_firmware PD_CAN_1>;
263 power-domains = <&zynqmp_firmware PD_GDMA>;
274 power-domains = <&zynqmp_firmware PD_GDMA>;
285 power-domains = <&zynqmp_firmware PD_GDMA>;
296 power-domains = <&zynqmp_firmware PD_GDMA>;
307 power-domains = <&zynqmp_firmware PD_GDMA>;
318 power-domains = <&zynqmp_firmware PD_GDMA>;
329 power-domains = <&zynqmp_firmware PD_GDMA>;
340 power-domains = <&zynqmp_firmware PD_GDMA>;
[all …]

12345678910>>...16