Home
last modified time | relevance | path

Searched refs:indicate (Results 1 – 25 of 54) sorted by relevance

123

/dpdk/doc/guides/sample_app_ug/
H A Dqos_metering.rst114 Where rows indicate the input color, columns indicate the output color,
H A Dptpclient.rst162 If the offload flags in the mbuf indicate that the packet is a PTP packet then
H A Ddist_app.rst85 (to indicate the output port which will be used later for packet transmission)
/dpdk/drivers/net/netvsc/
H A Dhn_rndis.c300 const struct rndis_status_msg *indicate = msg; in hn_rndis_link_status() local
304 PMD_DRV_LOG(DEBUG, "link status %#x", indicate->status); in hn_rndis_link_status()
306 switch (indicate->status) { in hn_rndis_link_status()
320 indicate->status); in hn_rndis_link_status()
/dpdk/doc/guides/contributing/
H A Dunit_test.rst303 &end_testsuite /**< NULL test suite to indicate end of list */
331 The first way to indicate a generic error is
354 Sometimes it is important to indicate that a test needs to be skipped,
359 to indicate that the preconditions of the test aren't available.
H A Dabi_policy.rst89 libraries' sonames are bumped to indicate the new version, with the minor
98 Minor versions are incremented to indicate the release of a new ABI compatible
100 be that ``librte_eal.so.21.1`` would indicate the first ABI compatible DPDK
250 an explicit package dependency, as the soname can only indicate the
H A Dstable.rst26 Release to indicate longer term support.
H A Dabi_versioning.rst410 Finally, we need to indicate to the :doc:`meson/ninja build system
419 at the start of the head of the file. This will indicate to the tool-chain to
/dpdk/doc/guides/gpus/
H A Dcuda.rst23 You need to indicate to meson where CUDA headers files are through the CFLAGS variable.
49 You need to indicate to meson where GDRCopy headers files are as in case of CUDA headers.
/dpdk/doc/guides/prog_guide/
H A Dipsec_lib.rst112 - update *ol_flags* inside *struct rte_mbuf* to indicate that
129 - update *ol_flags* inside *struct rte_mbuf* to indicate that
H A Dmember_lib.rst166 the property of vBF to indicate right away that a given flow is a new one or
206 Along with the signature, HTSS also stores a value to indicate the target set.
294 set-summary. For HTSS, another parameter ``is_cache`` is used to indicate
313 value is 1 to indicate such situation, but it is not an error.
347 element/key that needs to be looked up, ``max_match_per_key`` which is to indicate the maximum numb…
H A Devent_timer_adapter.rst51 * ``event_priority`` - Application can set this to indicate the priority of the
55 * ``flow_id`` - Application can set this to indicate which flow this timer
H A Dpacket_distrib_lib.rst93 …to have a worker stop processing packets by calling "rte_distributor_return_pkt()" to indicate that
H A Devent_ethernet_tx_adapter.rst64 of -1 is used to indicate all queues within a device.
H A Deventdev.rst145 There is a SINGLE_LINK flag which allows an application to indicate that only
376 indicate to the worker what workload needs to be performed on the event.
H A Dgpudev.rst57 required to indicate which device a given operation should be executed on.
H A Dmetrics_lib.rst294 ``ol_flags`` for the mbuf to indicate the marked time as a valid one.
/dpdk/doc/guides/cryptodevs/
H A Dcaam_jr.rst37 indicate the operations to be performed and link to the message and
H A Ddpaa_sec.rst39 indicate the operations to be performed and link to the message and
H A Ddpaa2_sec.rst55 indicate the operations to be performed and link to the message and
/dpdk/doc/guides/howto/
H A Dtelemetry.rst84 * Get the help text for a command. This will indicate what parameters are
/dpdk/doc/guides/linux_gsg/
H A Dnic_perf_intel_platform.rst83 When inserting NICs into PCI slots always check the caption, such as CPU0 or CPU1 to indicate which…
/dpdk/doc/guides/rel_notes/
H A Drelease_21_11.rst515 renamed to ``aux_flags`` to indicate warnings and other information from
581 ``rte_security_ipsec_sa_options`` to indicate whether outer header
585 ``rte_security_ipsec_sa_options`` to indicate whether UDP ports
594 in structure ``rte_security_ipsec_sa_options`` to indicate whether inner
/dpdk/doc/guides/nics/
H A Dnetvsc.rst112 A netvsc device uses a mailbox page to indicate to the host that there
H A Denic.rst282 Good checksum flags (e.g. ``RTE_MBUF_F_RX_L4_CKSUM_GOOD``) indicate that the inner
285 indicate that the inner and/or outer packets have invalid checksum values.
290 ``RTE_PTYPE_TUNNEL_GRENAT`` to indicate that the packet is tunneled.

123