1 // SPDX-License-Identifier: BSD-3-Clause
2 /*
3 * Copyright 2018 Mellanox Technologies, Ltd
4 */
5 #include <math.h>
6
7 #include <rte_tailq.h>
8 #include <rte_malloc.h>
9 #include <rte_mtr.h>
10 #include <rte_mtr_driver.h>
11
12 #include <mlx5_devx_cmds.h>
13 #include <mlx5_malloc.h>
14
15 #include "mlx5.h"
16 #include "mlx5_flow.h"
17
18 /**
19 * Create the meter action.
20 *
21 * @param priv
22 * Pointer to mlx5_priv.
23 * @param[in] fm
24 * Pointer to flow meter to be converted.
25 *
26 * @return
27 * Pointer to the meter action on success, NULL otherwise.
28 */
29 static void *
mlx5_flow_meter_action_create(struct mlx5_priv * priv,struct mlx5_flow_meter * fm)30 mlx5_flow_meter_action_create(struct mlx5_priv *priv,
31 struct mlx5_flow_meter *fm)
32 {
33 #ifdef HAVE_MLX5_DR_CREATE_ACTION_FLOW_METER
34 struct mlx5dv_dr_flow_meter_attr mtr_init;
35 void *attr = fm->mfts->fmp;
36 struct mlx5_flow_meter_srtcm_rfc2697_prm *srtcm =
37 &fm->profile->srtcm_prm;
38
39 fm->mfts->fmp_size = MLX5_ST_SZ_BYTES(flow_meter_parameters);
40 memset(attr, 0, fm->mfts->fmp_size);
41 MLX5_SET(flow_meter_parameters, attr, valid, 1);
42 MLX5_SET(flow_meter_parameters, attr, bucket_overflow, 1);
43 MLX5_SET(flow_meter_parameters, attr,
44 start_color, MLX5_FLOW_COLOR_GREEN);
45 MLX5_SET(flow_meter_parameters, attr, both_buckets_on_green, 0);
46 MLX5_SET(flow_meter_parameters,
47 attr, cbs_exponent, srtcm->cbs_exponent);
48 MLX5_SET(flow_meter_parameters,
49 attr, cbs_mantissa, srtcm->cbs_mantissa);
50 MLX5_SET(flow_meter_parameters,
51 attr, cir_exponent, srtcm->cir_exponent);
52 MLX5_SET(flow_meter_parameters,
53 attr, cir_mantissa, srtcm->cir_mantissa);
54 MLX5_SET(flow_meter_parameters,
55 attr, ebs_exponent, srtcm->ebs_exponent);
56 MLX5_SET(flow_meter_parameters,
57 attr, ebs_mantissa, srtcm->ebs_mantissa);
58 mtr_init.next_table =
59 fm->transfer ? fm->mfts->transfer.tbl->obj :
60 fm->egress ? fm->mfts->egress.tbl->obj :
61 fm->mfts->ingress.tbl->obj;
62 mtr_init.reg_c_index = priv->mtr_color_reg - REG_C_0;
63 mtr_init.flow_meter_parameter = fm->mfts->fmp;
64 mtr_init.flow_meter_parameter_sz = fm->mfts->fmp_size;
65 mtr_init.active = fm->active_state;
66 return mlx5_glue->dv_create_flow_action_meter(&mtr_init);
67 #else
68 (void)priv;
69 (void)fm;
70 return NULL;
71 #endif
72 }
73
74 /**
75 * Find meter profile by id.
76 *
77 * @param priv
78 * Pointer to mlx5_priv.
79 * @param meter_profile_id
80 * Meter profile id.
81 *
82 * @return
83 * Pointer to the profile found on success, NULL otherwise.
84 */
85 static struct mlx5_flow_meter_profile *
mlx5_flow_meter_profile_find(struct mlx5_priv * priv,uint32_t meter_profile_id)86 mlx5_flow_meter_profile_find(struct mlx5_priv *priv, uint32_t meter_profile_id)
87 {
88 struct mlx5_mtr_profiles *fmps = &priv->flow_meter_profiles;
89 struct mlx5_flow_meter_profile *fmp;
90
91 TAILQ_FOREACH(fmp, fmps, next)
92 if (meter_profile_id == fmp->meter_profile_id)
93 return fmp;
94 return NULL;
95 }
96
97 /**
98 * Validate the MTR profile.
99 *
100 * @param[in] dev
101 * Pointer to Ethernet device.
102 * @param[in] meter_profile_id
103 * Meter profile id.
104 * @param[in] profile
105 * Pointer to meter profile detail.
106 * @param[out] error
107 * Pointer to the error structure.
108 *
109 * @return
110 * 0 on success, a negative errno value otherwise and rte_errno is set.
111 */
112 static int
mlx5_flow_meter_profile_validate(struct rte_eth_dev * dev,uint32_t meter_profile_id,struct rte_mtr_meter_profile * profile,struct rte_mtr_error * error)113 mlx5_flow_meter_profile_validate(struct rte_eth_dev *dev,
114 uint32_t meter_profile_id,
115 struct rte_mtr_meter_profile *profile,
116 struct rte_mtr_error *error)
117 {
118 struct mlx5_priv *priv = dev->data->dev_private;
119 struct mlx5_flow_meter_profile *fmp;
120
121 /* Profile must not be NULL. */
122 if (profile == NULL)
123 return -rte_mtr_error_set(error, EINVAL,
124 RTE_MTR_ERROR_TYPE_METER_PROFILE,
125 NULL, "Meter profile is null.");
126 /* Meter profile ID must be valid. */
127 if (meter_profile_id == UINT32_MAX)
128 return -rte_mtr_error_set(error, EINVAL,
129 RTE_MTR_ERROR_TYPE_METER_PROFILE_ID,
130 NULL, "Meter profile id not valid.");
131 /* Meter profile must not exist. */
132 fmp = mlx5_flow_meter_profile_find(priv, meter_profile_id);
133 if (fmp)
134 return -rte_mtr_error_set(error, EEXIST,
135 RTE_MTR_ERROR_TYPE_METER_PROFILE_ID,
136 NULL,
137 "Meter profile already exists.");
138 if (profile->alg == RTE_MTR_SRTCM_RFC2697) {
139 if (priv->config.hca_attr.qos.srtcm_sup) {
140 /* Verify support for flow meter parameters. */
141 if (profile->srtcm_rfc2697.cir > 0 &&
142 profile->srtcm_rfc2697.cir <= MLX5_SRTCM_CIR_MAX &&
143 profile->srtcm_rfc2697.cbs > 0 &&
144 profile->srtcm_rfc2697.cbs <= MLX5_SRTCM_CBS_MAX &&
145 profile->srtcm_rfc2697.ebs <= MLX5_SRTCM_EBS_MAX)
146 return 0;
147 else
148 return -rte_mtr_error_set
149 (error, ENOTSUP,
150 RTE_MTR_ERROR_TYPE_MTR_PARAMS,
151 NULL,
152 profile->srtcm_rfc2697.ebs ?
153 "Metering value ebs must be 0." :
154 "Invalid metering parameters.");
155 }
156 }
157 return -rte_mtr_error_set(error, ENOTSUP,
158 RTE_MTR_ERROR_TYPE_METER_PROFILE,
159 NULL, "Metering algorithm not supported.");
160 }
161
162 /**
163 * Calculate mantissa and exponent for cir.
164 *
165 * @param[in] cir
166 * Value to be calculated.
167 * @param[out] man
168 * Pointer to the mantissa.
169 * @param[out] exp
170 * Pointer to the exp.
171 */
172 static void
mlx5_flow_meter_cir_man_exp_calc(int64_t cir,uint8_t * man,uint8_t * exp)173 mlx5_flow_meter_cir_man_exp_calc(int64_t cir, uint8_t *man, uint8_t *exp)
174 {
175 int64_t _cir;
176 int64_t delta = INT64_MAX;
177 uint8_t _man = 0;
178 uint8_t _exp = 0;
179 uint64_t m, e;
180
181 for (m = 0; m <= 0xFF; m++) { /* man width 8 bit */
182 for (e = 0; e <= 0x1F; e++) { /* exp width 5bit */
183 _cir = (1000000000ULL * m) >> e;
184 if (llabs(cir - _cir) <= delta) {
185 delta = llabs(cir - _cir);
186 _man = m;
187 _exp = e;
188 }
189 }
190 }
191 *man = _man;
192 *exp = _exp;
193 }
194
195 /**
196 * Calculate mantissa and exponent for xbs.
197 *
198 * @param[in] xbs
199 * Value to be calculated.
200 * @param[out] man
201 * Pointer to the mantissa.
202 * @param[out] exp
203 * Pointer to the exp.
204 */
205 static void
mlx5_flow_meter_xbs_man_exp_calc(uint64_t xbs,uint8_t * man,uint8_t * exp)206 mlx5_flow_meter_xbs_man_exp_calc(uint64_t xbs, uint8_t *man, uint8_t *exp)
207 {
208 int _exp;
209 double _man;
210
211 /* Special case xbs == 0 ? both exp and matissa are 0. */
212 if (xbs == 0) {
213 *man = 0;
214 *exp = 0;
215 return;
216 }
217 /* xbs = xbs_mantissa * 2^xbs_exponent */
218 _man = frexp(xbs, &_exp);
219 _man = _man * pow(2, MLX5_MAN_WIDTH);
220 _exp = _exp - MLX5_MAN_WIDTH;
221 *man = (uint8_t)ceil(_man);
222 *exp = _exp;
223 }
224
225 /**
226 * Fill the prm meter parameter.
227 *
228 * @param[in,out] fmp
229 * Pointer to meter profie to be converted.
230 * @param[out] error
231 * Pointer to the error structure.
232 *
233 * @return
234 * 0 on success, a negative errno value otherwise and rte_errno is set.
235 */
236 static int
mlx5_flow_meter_param_fill(struct mlx5_flow_meter_profile * fmp,struct rte_mtr_error * error)237 mlx5_flow_meter_param_fill(struct mlx5_flow_meter_profile *fmp,
238 struct rte_mtr_error *error)
239 {
240 struct mlx5_flow_meter_srtcm_rfc2697_prm *srtcm = &fmp->srtcm_prm;
241 uint8_t man, exp;
242
243 if (fmp->profile.alg != RTE_MTR_SRTCM_RFC2697)
244 return -rte_mtr_error_set(error, ENOTSUP,
245 RTE_MTR_ERROR_TYPE_METER_PROFILE,
246 NULL, "Metering algorithm not supported.");
247 /* cbs = cbs_mantissa * 2^cbs_exponent */
248 mlx5_flow_meter_xbs_man_exp_calc(fmp->profile.srtcm_rfc2697.cbs,
249 &man, &exp);
250 srtcm->cbs_mantissa = man;
251 srtcm->cbs_exponent = exp;
252 /* Check if cbs mantissa is too large. */
253 if (srtcm->cbs_exponent != exp)
254 return -rte_mtr_error_set(error, EINVAL,
255 RTE_MTR_ERROR_TYPE_MTR_PARAMS, NULL,
256 "Metering profile parameter cbs is"
257 " invalid.");
258 /* ebs = ebs_mantissa * 2^ebs_exponent */
259 mlx5_flow_meter_xbs_man_exp_calc(fmp->profile.srtcm_rfc2697.ebs,
260 &man, &exp);
261 srtcm->ebs_mantissa = man;
262 srtcm->ebs_exponent = exp;
263 /* Check if ebs mantissa is too large. */
264 if (srtcm->ebs_exponent != exp)
265 return -rte_mtr_error_set(error, EINVAL,
266 RTE_MTR_ERROR_TYPE_MTR_PARAMS, NULL,
267 "Metering profile parameter ebs is"
268 " invalid.");
269 /* cir = 8G * cir_mantissa * 1/(2^cir_exponent)) Bytes/Sec */
270 mlx5_flow_meter_cir_man_exp_calc(fmp->profile.srtcm_rfc2697.cir,
271 &man, &exp);
272 srtcm->cir_mantissa = man;
273 srtcm->cir_exponent = exp;
274 /* Check if cir mantissa is too large. */
275 if (srtcm->cir_exponent != exp)
276 return -rte_mtr_error_set(error, EINVAL,
277 RTE_MTR_ERROR_TYPE_MTR_PARAMS, NULL,
278 "Metering profile parameter cir is"
279 " invalid.");
280 return 0;
281 }
282
283 /**
284 * Callback to get MTR capabilities.
285 *
286 * @param[in] dev
287 * Pointer to Ethernet device.
288 * @param[out] cap
289 * Pointer to save MTR capabilities.
290 * @param[out] error
291 * Pointer to the error structure.
292 *
293 * @return
294 * 0 on success, a negative errno value otherwise and rte_errno is set.
295 */
296 static int
mlx5_flow_mtr_cap_get(struct rte_eth_dev * dev,struct rte_mtr_capabilities * cap,struct rte_mtr_error * error __rte_unused)297 mlx5_flow_mtr_cap_get(struct rte_eth_dev *dev,
298 struct rte_mtr_capabilities *cap,
299 struct rte_mtr_error *error __rte_unused)
300 {
301 struct mlx5_priv *priv = dev->data->dev_private;
302 struct mlx5_hca_qos_attr *qattr = &priv->config.hca_attr.qos;
303
304 if (!priv->mtr_en)
305 return -rte_mtr_error_set(error, ENOTSUP,
306 RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
307 "Meter is not supported");
308 memset(cap, 0, sizeof(*cap));
309 cap->n_max = 1 << qattr->log_max_flow_meter;
310 cap->n_shared_max = cap->n_max;
311 cap->identical = 1;
312 cap->shared_identical = 1;
313 cap->shared_n_flows_per_mtr_max = 4 << 20;
314 /* 2M flows can share the same meter. */
315 cap->chaining_n_mtrs_per_flow_max = 1; /* Chaining is not supported. */
316 cap->meter_srtcm_rfc2697_n_max = qattr->srtcm_sup ? cap->n_max : 0;
317 cap->meter_rate_max = 1ULL << 40; /* 1 Tera tokens per sec. */
318 cap->policer_action_drop_supported = 1;
319 cap->stats_mask = RTE_MTR_STATS_N_BYTES_DROPPED |
320 RTE_MTR_STATS_N_PKTS_DROPPED;
321 return 0;
322 }
323
324 /**
325 * Callback to add MTR profile.
326 *
327 * @param[in] dev
328 * Pointer to Ethernet device.
329 * @param[in] meter_profile_id
330 * Meter profile id.
331 * @param[in] profile
332 * Pointer to meter profile detail.
333 * @param[out] error
334 * Pointer to the error structure.
335 *
336 * @return
337 * 0 on success, a negative errno value otherwise and rte_errno is set.
338 */
339 static int
mlx5_flow_meter_profile_add(struct rte_eth_dev * dev,uint32_t meter_profile_id,struct rte_mtr_meter_profile * profile,struct rte_mtr_error * error)340 mlx5_flow_meter_profile_add(struct rte_eth_dev *dev,
341 uint32_t meter_profile_id,
342 struct rte_mtr_meter_profile *profile,
343 struct rte_mtr_error *error)
344 {
345 struct mlx5_priv *priv = dev->data->dev_private;
346 struct mlx5_mtr_profiles *fmps = &priv->flow_meter_profiles;
347 struct mlx5_flow_meter_profile *fmp;
348 int ret;
349
350 if (!priv->mtr_en)
351 return -rte_mtr_error_set(error, ENOTSUP,
352 RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
353 "Meter is not supported");
354 /* Check input params. */
355 ret = mlx5_flow_meter_profile_validate(dev, meter_profile_id,
356 profile, error);
357 if (ret)
358 return ret;
359 /* Meter profile memory allocation. */
360 fmp = mlx5_malloc(MLX5_MEM_ZERO, sizeof(struct mlx5_flow_meter_profile),
361 RTE_CACHE_LINE_SIZE, SOCKET_ID_ANY);
362 if (fmp == NULL)
363 return -rte_mtr_error_set(error, ENOMEM,
364 RTE_MTR_ERROR_TYPE_UNSPECIFIED,
365 NULL, "Meter profile memory "
366 "alloc failed.");
367 /* Fill profile info. */
368 fmp->meter_profile_id = meter_profile_id;
369 fmp->profile = *profile;
370 /* Fill the flow meter parameters for the PRM. */
371 ret = mlx5_flow_meter_param_fill(fmp, error);
372 if (ret)
373 goto error;
374 /* Add to list. */
375 TAILQ_INSERT_TAIL(fmps, fmp, next);
376 return 0;
377 error:
378 mlx5_free(fmp);
379 return ret;
380 }
381
382 /**
383 * Callback to delete MTR profile.
384 *
385 * @param[in] dev
386 * Pointer to Ethernet device.
387 * @param[in] meter_profile_id
388 * Meter profile id.
389 * @param[out] error
390 * Pointer to the error structure.
391 *
392 * @return
393 * 0 on success, a negative errno value otherwise and rte_errno is set.
394 */
395 static int
mlx5_flow_meter_profile_delete(struct rte_eth_dev * dev,uint32_t meter_profile_id,struct rte_mtr_error * error)396 mlx5_flow_meter_profile_delete(struct rte_eth_dev *dev,
397 uint32_t meter_profile_id,
398 struct rte_mtr_error *error)
399 {
400 struct mlx5_priv *priv = dev->data->dev_private;
401 struct mlx5_flow_meter_profile *fmp;
402
403 if (!priv->mtr_en)
404 return -rte_mtr_error_set(error, ENOTSUP,
405 RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
406 "Meter is not supported");
407 /* Meter profile must exist. */
408 fmp = mlx5_flow_meter_profile_find(priv, meter_profile_id);
409 if (fmp == NULL)
410 return -rte_mtr_error_set(error, ENOENT,
411 RTE_MTR_ERROR_TYPE_METER_PROFILE_ID,
412 &meter_profile_id,
413 "Meter profile id is invalid.");
414 /* Check profile is unused. */
415 if (fmp->ref_cnt)
416 return -rte_mtr_error_set(error, EBUSY,
417 RTE_MTR_ERROR_TYPE_METER_PROFILE_ID,
418 NULL, "Meter profile is in use.");
419 /* Remove from list. */
420 TAILQ_REMOVE(&priv->flow_meter_profiles, fmp, next);
421 mlx5_free(fmp);
422 return 0;
423 }
424
425 /**
426 * Convert wrong color setting action to verbose error.
427 *
428 * @param[in] action
429 * Policy color action.
430 *
431 * @return
432 * Verbose meter color error type.
433 */
434 static inline enum rte_mtr_error_type
action2error(enum rte_mtr_policer_action action)435 action2error(enum rte_mtr_policer_action action)
436 {
437 switch (action) {
438 case MTR_POLICER_ACTION_COLOR_GREEN:
439 return RTE_MTR_ERROR_TYPE_POLICER_ACTION_GREEN;
440 case MTR_POLICER_ACTION_COLOR_YELLOW:
441 return RTE_MTR_ERROR_TYPE_POLICER_ACTION_YELLOW;
442 case MTR_POLICER_ACTION_COLOR_RED:
443 return RTE_MTR_ERROR_TYPE_POLICER_ACTION_RED;
444 default:
445 break;
446 }
447 return RTE_MTR_ERROR_TYPE_UNSPECIFIED;
448 }
449
450 /**
451 * Check meter validation.
452 *
453 * @param[in] priv
454 * Pointer to mlx5 private data structure.
455 * @param[in] meter_id
456 * Meter id.
457 * @param[in] params
458 * Pointer to rte meter parameters.
459 * @param[out] error
460 * Pointer to rte meter error structure.
461 *
462 * @return
463 * 0 on success, a negative errno value otherwise and rte_errno is set.
464 */
465 static int
mlx5_flow_meter_validate(struct mlx5_priv * priv,uint32_t meter_id,struct rte_mtr_params * params,struct rte_mtr_error * error)466 mlx5_flow_meter_validate(struct mlx5_priv *priv, uint32_t meter_id,
467 struct rte_mtr_params *params,
468 struct rte_mtr_error *error)
469 {
470 static enum rte_mtr_policer_action
471 valid_recol_action[RTE_COLORS] = {
472 MTR_POLICER_ACTION_COLOR_GREEN,
473 MTR_POLICER_ACTION_COLOR_YELLOW,
474 MTR_POLICER_ACTION_COLOR_RED };
475 int i;
476
477 /* Meter params must not be NULL. */
478 if (params == NULL)
479 return -rte_mtr_error_set(error, EINVAL,
480 RTE_MTR_ERROR_TYPE_MTR_PARAMS,
481 NULL, "Meter object params null.");
482 /* Previous meter color is not supported. */
483 if (params->use_prev_mtr_color)
484 return -rte_mtr_error_set(error, ENOTSUP,
485 RTE_MTR_ERROR_TYPE_MTR_PARAMS,
486 NULL,
487 "Previous meter color "
488 "not supported.");
489 /* Validate policer settings. */
490 for (i = 0; i < RTE_COLORS; i++)
491 if (params->action[i] != valid_recol_action[i] &&
492 params->action[i] != MTR_POLICER_ACTION_DROP)
493 return -rte_mtr_error_set
494 (error, ENOTSUP,
495 action2error(params->action[i]), NULL,
496 "Recolor action not supported.");
497 /* Validate meter id. */
498 if (mlx5_flow_meter_find(priv, meter_id))
499 return -rte_mtr_error_set(error, EEXIST,
500 RTE_MTR_ERROR_TYPE_MTR_ID, NULL,
501 "Meter object already exists.");
502 return 0;
503 }
504
505 /**
506 * Modify the flow meter action.
507 *
508 * @param[in] priv
509 * Pointer to mlx5 private data structure.
510 * @param[in] fm
511 * Pointer to flow meter to be modified.
512 * @param[in] srtcm
513 * Pointer to meter srtcm description parameter.
514 * @param[in] modify_bits
515 * The bit in srtcm to be updated.
516 * @param[in] active_state
517 * The state to be updated.
518 * @return
519 * 0 on success, o negative value otherwise.
520 */
521 static int
mlx5_flow_meter_action_modify(struct mlx5_priv * priv,struct mlx5_flow_meter * fm,const struct mlx5_flow_meter_srtcm_rfc2697_prm * srtcm,uint64_t modify_bits,uint32_t active_state)522 mlx5_flow_meter_action_modify(struct mlx5_priv *priv,
523 struct mlx5_flow_meter *fm,
524 const struct mlx5_flow_meter_srtcm_rfc2697_prm *srtcm,
525 uint64_t modify_bits, uint32_t active_state)
526 {
527 #ifdef HAVE_MLX5_DR_CREATE_ACTION_FLOW_METER
528 uint32_t in[MLX5_ST_SZ_DW(flow_meter_parameters)] = { 0 };
529 uint32_t *attr;
530 struct mlx5dv_dr_flow_meter_attr mod_attr = { 0 };
531 int ret;
532
533 /* Fill command parameters. */
534 mod_attr.reg_c_index = priv->mtr_color_reg - REG_C_0;
535 mod_attr.flow_meter_parameter = in;
536 mod_attr.flow_meter_parameter_sz = fm->mfts->fmp_size;
537 if (modify_bits & MLX5_FLOW_METER_OBJ_MODIFY_FIELD_ACTIVE)
538 mod_attr.active = !!active_state;
539 else
540 mod_attr.active = 0;
541 attr = in;
542 if (modify_bits & MLX5_FLOW_METER_OBJ_MODIFY_FIELD_CBS) {
543 MLX5_SET(flow_meter_parameters,
544 attr, cbs_exponent, srtcm->cbs_exponent);
545 MLX5_SET(flow_meter_parameters,
546 attr, cbs_mantissa, srtcm->cbs_mantissa);
547 }
548 if (modify_bits & MLX5_FLOW_METER_OBJ_MODIFY_FIELD_CIR) {
549 MLX5_SET(flow_meter_parameters,
550 attr, cir_exponent, srtcm->cir_exponent);
551 MLX5_SET(flow_meter_parameters,
552 attr, cir_mantissa, srtcm->cir_mantissa);
553 }
554 if (modify_bits & MLX5_FLOW_METER_OBJ_MODIFY_FIELD_EBS) {
555 MLX5_SET(flow_meter_parameters,
556 attr, ebs_exponent, srtcm->ebs_exponent);
557 MLX5_SET(flow_meter_parameters,
558 attr, ebs_mantissa, srtcm->ebs_mantissa);
559 }
560 /* Apply modifications to meter only if it was created. */
561 if (fm->mfts->meter_action) {
562 ret = mlx5_glue->dv_modify_flow_action_meter
563 (fm->mfts->meter_action, &mod_attr,
564 rte_cpu_to_be_64(modify_bits));
565 if (ret)
566 return ret;
567 }
568 /* Update succeedded modify meter parameters. */
569 if (modify_bits & MLX5_FLOW_METER_OBJ_MODIFY_FIELD_ACTIVE)
570 fm->active_state = !!active_state;
571 attr = fm->mfts->fmp;
572 if (modify_bits & MLX5_FLOW_METER_OBJ_MODIFY_FIELD_CBS) {
573 MLX5_SET(flow_meter_parameters,
574 attr, cbs_exponent, srtcm->cbs_exponent);
575 MLX5_SET(flow_meter_parameters,
576 attr, cbs_mantissa, srtcm->cbs_mantissa);
577 }
578 if (modify_bits & MLX5_FLOW_METER_OBJ_MODIFY_FIELD_CIR) {
579 MLX5_SET(flow_meter_parameters,
580 attr, cir_exponent, srtcm->cir_exponent);
581 MLX5_SET(flow_meter_parameters,
582 attr, cir_mantissa, srtcm->cir_mantissa);
583 }
584 if (modify_bits & MLX5_FLOW_METER_OBJ_MODIFY_FIELD_EBS) {
585 MLX5_SET(flow_meter_parameters,
586 attr, ebs_exponent, srtcm->ebs_exponent);
587 MLX5_SET(flow_meter_parameters,
588 attr, ebs_mantissa, srtcm->ebs_mantissa);
589 }
590
591 return 0;
592 #else
593 (void)priv;
594 (void)fm;
595 (void)srtcm;
596 (void)modify_bits;
597 (void)active_state;
598 return -ENOTSUP;
599 #endif
600 }
601
602 /**
603 * Create meter rules.
604 *
605 * @param[in] dev
606 * Pointer to Ethernet device.
607 * @param[in] meter_id
608 * Meter id.
609 * @param[in] params
610 * Pointer to rte meter parameters.
611 * @param[in] shared
612 * Meter shared with other flow or not.
613 * @param[out] error
614 * Pointer to rte meter error structure.
615 *
616 * @return
617 * 0 on success, a negative errno value otherwise and rte_errno is set.
618 */
619 static int
mlx5_flow_meter_create(struct rte_eth_dev * dev,uint32_t meter_id,struct rte_mtr_params * params,int shared,struct rte_mtr_error * error)620 mlx5_flow_meter_create(struct rte_eth_dev *dev, uint32_t meter_id,
621 struct rte_mtr_params *params, int shared,
622 struct rte_mtr_error *error)
623 {
624 struct mlx5_priv *priv = dev->data->dev_private;
625 struct mlx5_flow_meters *fms = &priv->flow_meters;
626 struct mlx5_flow_meter_profile *fmp;
627 struct mlx5_flow_meter *fm;
628 const struct rte_flow_attr attr = {
629 .ingress = 1,
630 .egress = 1,
631 .transfer = priv->config.dv_esw_en ? 1 : 0,
632 };
633 int ret;
634 unsigned int i;
635 uint32_t idx = 0;
636
637 if (!priv->mtr_en)
638 return -rte_mtr_error_set(error, ENOTSUP,
639 RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
640 "Meter is not supported");
641 /* Validate the parameters. */
642 ret = mlx5_flow_meter_validate(priv, meter_id, params, error);
643 if (ret)
644 return ret;
645 /* Meter profile must exist. */
646 fmp = mlx5_flow_meter_profile_find(priv, params->meter_profile_id);
647 if (fmp == NULL)
648 return -rte_mtr_error_set(error, ENOENT,
649 RTE_MTR_ERROR_TYPE_METER_PROFILE_ID,
650 NULL, "Meter profile id not valid.");
651 /* Allocate the flow meter memory. */
652 fm = mlx5_ipool_zmalloc(priv->sh->ipool[MLX5_IPOOL_MTR], &idx);
653 if (fm == NULL)
654 return -rte_mtr_error_set(error, ENOMEM,
655 RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
656 "Memory alloc failed for meter.");
657 fm->idx = idx;
658 /* Fill the flow meter parameters. */
659 fm->meter_id = meter_id;
660 fm->profile = fmp;
661 memcpy(fm->action, params->action, sizeof(params->action));
662 fm->stats_mask = params->stats_mask;
663
664 /* Alloc policer counters. */
665 for (i = 0; i < RTE_DIM(fm->policer_stats.cnt); i++) {
666 fm->policer_stats.cnt[i] = mlx5_counter_alloc(dev);
667 if (!fm->policer_stats.cnt[i])
668 goto error;
669 }
670 fm->mfts = mlx5_flow_create_mtr_tbls(dev, fm);
671 if (!fm->mfts)
672 goto error;
673 ret = mlx5_flow_create_policer_rules(dev, fm, &attr);
674 if (ret)
675 goto error;
676 /* Add to the flow meter list. */
677 TAILQ_INSERT_TAIL(fms, fm, next);
678 fm->active_state = 1; /* Config meter starts as active. */
679 fm->shared = !!shared;
680 fm->policer_stats.stats_mask = params->stats_mask;
681 fm->profile->ref_cnt++;
682 rte_spinlock_init(&fm->sl);
683 return 0;
684 error:
685 mlx5_flow_destroy_policer_rules(dev, fm, &attr);
686 mlx5_flow_destroy_mtr_tbls(dev, fm->mfts);
687 /* Free policer counters. */
688 for (i = 0; i < RTE_DIM(fm->policer_stats.cnt); i++)
689 if (fm->policer_stats.cnt[i])
690 mlx5_counter_free(dev, fm->policer_stats.cnt[i]);
691 mlx5_ipool_free(priv->sh->ipool[MLX5_IPOOL_MTR], idx);
692 return -rte_mtr_error_set(error, -ret,
693 RTE_MTR_ERROR_TYPE_UNSPECIFIED,
694 NULL, "Failed to create devx meter.");
695 }
696
697 /**
698 * Destroy meter rules.
699 *
700 * @param[in] dev
701 * Pointer to Ethernet device.
702 * @param[in] meter_id
703 * Meter id.
704 * @param[out] error
705 * Pointer to rte meter error structure.
706 *
707 * @return
708 * 0 on success, a negative errno value otherwise and rte_errno is set.
709 */
710 static int
mlx5_flow_meter_destroy(struct rte_eth_dev * dev,uint32_t meter_id,struct rte_mtr_error * error)711 mlx5_flow_meter_destroy(struct rte_eth_dev *dev, uint32_t meter_id,
712 struct rte_mtr_error *error)
713 {
714 struct mlx5_priv *priv = dev->data->dev_private;
715 struct mlx5_flow_meters *fms = &priv->flow_meters;
716 struct mlx5_flow_meter_profile *fmp;
717 struct mlx5_flow_meter *fm;
718 const struct rte_flow_attr attr = {
719 .ingress = 1,
720 .egress = 1,
721 .transfer = priv->config.dv_esw_en ? 1 : 0,
722 };
723 unsigned int i;
724
725 if (!priv->mtr_en)
726 return -rte_mtr_error_set(error, ENOTSUP,
727 RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
728 "Meter is not supported");
729 /* Meter object must exist. */
730 fm = mlx5_flow_meter_find(priv, meter_id);
731 if (fm == NULL)
732 return -rte_mtr_error_set(error, ENOENT,
733 RTE_MTR_ERROR_TYPE_MTR_ID,
734 NULL, "Meter object id not valid.");
735 /* Meter object must not have any owner. */
736 if (fm->ref_cnt > 0)
737 return -rte_mtr_error_set(error, EBUSY,
738 RTE_MTR_ERROR_TYPE_UNSPECIFIED,
739 NULL, "Meter object is being used.");
740 /* Get the meter profile. */
741 fmp = fm->profile;
742 MLX5_ASSERT(fmp);
743 /* Update dependencies. */
744 fmp->ref_cnt--;
745 /* Remove from the flow meter list. */
746 TAILQ_REMOVE(fms, fm, next);
747 /* Free policer counters. */
748 for (i = 0; i < RTE_DIM(fm->policer_stats.cnt); i++)
749 if (fm->policer_stats.cnt[i])
750 mlx5_counter_free(dev, fm->policer_stats.cnt[i]);
751 /* Free meter flow table */
752 mlx5_flow_destroy_policer_rules(dev, fm, &attr);
753 mlx5_flow_destroy_mtr_tbls(dev, fm->mfts);
754 mlx5_ipool_free(priv->sh->ipool[MLX5_IPOOL_MTR], fm->idx);
755 return 0;
756 }
757
758 /**
759 * Modify meter state.
760 *
761 * @param[in] priv
762 * Pointer to mlx5 private data structure.
763 * @param[in] fm
764 * Pointer to flow meter.
765 * @param[in] new_state
766 * New state to update.
767 * @param[out] error
768 * Pointer to rte meter error structure.
769 *
770 * @return
771 * 0 on success, a negative errno value otherwise and rte_errno is set.
772 */
773 static int
mlx5_flow_meter_modify_state(struct mlx5_priv * priv,struct mlx5_flow_meter * fm,uint32_t new_state,struct rte_mtr_error * error)774 mlx5_flow_meter_modify_state(struct mlx5_priv *priv,
775 struct mlx5_flow_meter *fm,
776 uint32_t new_state,
777 struct rte_mtr_error *error)
778 {
779 static const struct mlx5_flow_meter_srtcm_rfc2697_prm srtcm = {
780 .cbs_exponent = 20,
781 .cbs_mantissa = 191,
782 .cir_exponent = 0,
783 .cir_mantissa = 200,
784 .ebs_exponent = 0,
785 .ebs_mantissa = 0,
786 };
787 uint64_t modify_bits = MLX5_FLOW_METER_OBJ_MODIFY_FIELD_CBS |
788 MLX5_FLOW_METER_OBJ_MODIFY_FIELD_CIR;
789 int ret;
790
791 if (new_state == MLX5_FLOW_METER_DISABLE)
792 ret = mlx5_flow_meter_action_modify(priv, fm, &srtcm,
793 modify_bits, 0);
794 else
795 ret = mlx5_flow_meter_action_modify(priv, fm,
796 &fm->profile->srtcm_prm,
797 modify_bits, 0);
798 if (ret)
799 return -rte_mtr_error_set(error, -ret,
800 RTE_MTR_ERROR_TYPE_MTR_PARAMS,
801 NULL,
802 new_state ?
803 "Failed to enable meter." :
804 "Failed to disable meter.");
805 return 0;
806 }
807
808 /**
809 * Callback to enable flow meter.
810 *
811 * @param[in] dev
812 * Pointer to Ethernet device.
813 * @param[in] meter_id
814 * Meter id.
815 * @param[out] error
816 * Pointer to rte meter error structure.
817 *
818 * @return
819 * 0 on success, a negative errno value otherwise and rte_errno is set.
820 */
821 static int
mlx5_flow_meter_enable(struct rte_eth_dev * dev,uint32_t meter_id,struct rte_mtr_error * error)822 mlx5_flow_meter_enable(struct rte_eth_dev *dev,
823 uint32_t meter_id,
824 struct rte_mtr_error *error)
825 {
826 struct mlx5_priv *priv = dev->data->dev_private;
827 struct mlx5_flow_meter *fm;
828 int ret;
829
830 if (!priv->mtr_en)
831 return -rte_mtr_error_set(error, ENOTSUP,
832 RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
833 "Meter is not supported");
834 /* Meter object must exist. */
835 fm = mlx5_flow_meter_find(priv, meter_id);
836 if (fm == NULL)
837 return -rte_mtr_error_set(error, ENOENT,
838 RTE_MTR_ERROR_TYPE_MTR_ID,
839 NULL, "Meter not found.");
840 if (fm->active_state == MLX5_FLOW_METER_ENABLE)
841 return 0;
842 ret = mlx5_flow_meter_modify_state(priv, fm, MLX5_FLOW_METER_ENABLE,
843 error);
844 if (!ret)
845 fm->active_state = MLX5_FLOW_METER_ENABLE;
846 return ret;
847 }
848
849 /**
850 * Callback to disable flow meter.
851 *
852 * @param[in] dev
853 * Pointer to Ethernet device.
854 * @param[in] meter_id
855 * Meter id.
856 * @param[out] error
857 * Pointer to rte meter error structure.
858 *
859 * @return
860 * 0 on success, a negative errno value otherwise and rte_errno is set.
861 */
862 static int
mlx5_flow_meter_disable(struct rte_eth_dev * dev,uint32_t meter_id,struct rte_mtr_error * error)863 mlx5_flow_meter_disable(struct rte_eth_dev *dev,
864 uint32_t meter_id,
865 struct rte_mtr_error *error)
866 {
867 struct mlx5_priv *priv = dev->data->dev_private;
868 struct mlx5_flow_meter *fm;
869 int ret;
870
871 if (!priv->mtr_en)
872 return -rte_mtr_error_set(error, ENOTSUP,
873 RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
874 "Meter is not supported");
875 /* Meter object must exist. */
876 fm = mlx5_flow_meter_find(priv, meter_id);
877 if (fm == NULL)
878 return -rte_mtr_error_set(error, ENOENT,
879 RTE_MTR_ERROR_TYPE_MTR_ID,
880 NULL, "Meter not found.");
881 if (fm->active_state == MLX5_FLOW_METER_DISABLE)
882 return 0;
883 ret = mlx5_flow_meter_modify_state(priv, fm, MLX5_FLOW_METER_DISABLE,
884 error);
885 if (!ret)
886 fm->active_state = MLX5_FLOW_METER_DISABLE;
887 return ret;
888 }
889
890 /**
891 * Callback to update meter profile.
892 *
893 * @param[in] dev
894 * Pointer to Ethernet device.
895 * @param[in] meter_id
896 * Meter id.
897 * @param[in] meter_profile_id
898 * To be updated meter profile id.
899 * @param[out] error
900 * Pointer to rte meter error structure.
901 *
902 * @return
903 * 0 on success, a negative errno value otherwise and rte_errno is set.
904 */
905 static int
mlx5_flow_meter_profile_update(struct rte_eth_dev * dev,uint32_t meter_id,uint32_t meter_profile_id,struct rte_mtr_error * error)906 mlx5_flow_meter_profile_update(struct rte_eth_dev *dev,
907 uint32_t meter_id,
908 uint32_t meter_profile_id,
909 struct rte_mtr_error *error)
910 {
911 struct mlx5_priv *priv = dev->data->dev_private;
912 struct mlx5_flow_meter_profile *fmp;
913 struct mlx5_flow_meter_profile *old_fmp;
914 struct mlx5_flow_meter *fm;
915 uint64_t modify_bits = MLX5_FLOW_METER_OBJ_MODIFY_FIELD_CBS |
916 MLX5_FLOW_METER_OBJ_MODIFY_FIELD_CIR;
917 int ret;
918
919 if (!priv->mtr_en)
920 return -rte_mtr_error_set(error, ENOTSUP,
921 RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
922 "Meter is not supported");
923 /* Meter profile must exist. */
924 fmp = mlx5_flow_meter_profile_find(priv, meter_profile_id);
925 if (fmp == NULL)
926 return -rte_mtr_error_set(error, ENOENT,
927 RTE_MTR_ERROR_TYPE_METER_PROFILE_ID,
928 NULL, "Meter profile not found.");
929 /* Meter object must exist. */
930 fm = mlx5_flow_meter_find(priv, meter_id);
931 if (fm == NULL)
932 return -rte_mtr_error_set(error, ENOENT,
933 RTE_MTR_ERROR_TYPE_MTR_ID,
934 NULL, "Meter not found.");
935 /* MTR object already set to meter profile id. */
936 old_fmp = fm->profile;
937 if (fmp == old_fmp)
938 return 0;
939 /* Update the profile. */
940 fm->profile = fmp;
941 /* Update meter params in HW (if not disabled). */
942 if (fm->active_state == MLX5_FLOW_METER_DISABLE)
943 return 0;
944 ret = mlx5_flow_meter_action_modify(priv, fm, &fm->profile->srtcm_prm,
945 modify_bits, fm->active_state);
946 if (ret) {
947 fm->profile = old_fmp;
948 return -rte_mtr_error_set(error, -ret,
949 RTE_MTR_ERROR_TYPE_MTR_PARAMS,
950 NULL, "Failed to update meter"
951 " parmeters in hardware.");
952 }
953 old_fmp->ref_cnt--;
954 fmp->ref_cnt++;
955 return 0;
956 }
957
958 /**
959 * Callback to update meter stats mask.
960 *
961 * @param[in] dev
962 * Pointer to Ethernet device.
963 * @param[in] meter_id
964 * Meter id.
965 * @param[in] stats_mask
966 * To be updated stats_mask.
967 * @param[out] error
968 * Pointer to rte meter error structure.
969 *
970 * @return
971 * 0 on success, a negative errno value otherwise and rte_errno is set.
972 */
973 static int
mlx5_flow_meter_stats_update(struct rte_eth_dev * dev,uint32_t meter_id,uint64_t stats_mask,struct rte_mtr_error * error)974 mlx5_flow_meter_stats_update(struct rte_eth_dev *dev,
975 uint32_t meter_id,
976 uint64_t stats_mask,
977 struct rte_mtr_error *error)
978 {
979 struct mlx5_priv *priv = dev->data->dev_private;
980 struct mlx5_flow_meter *fm;
981
982 if (!priv->mtr_en)
983 return -rte_mtr_error_set(error, ENOTSUP,
984 RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
985 "Meter is not supported");
986 /* Meter object must exist. */
987 fm = mlx5_flow_meter_find(priv, meter_id);
988 if (fm == NULL)
989 return -rte_mtr_error_set(error, ENOENT,
990 RTE_MTR_ERROR_TYPE_MTR_ID,
991 NULL, "Meter object id not valid.");
992 fm->policer_stats.stats_mask = stats_mask;
993 return 0;
994 }
995
996 /**
997 * Callback to read meter statistics.
998 *
999 * @param[in] dev
1000 * Pointer to Ethernet device.
1001 * @param[in] meter_id
1002 * Meter id.
1003 * @param[out] stats
1004 * Pointer to store the statistics.
1005 * @param[out] stats_mask
1006 * Pointer to store the stats_mask.
1007 * @param[in] clear
1008 * Statistic to be cleared after read or not.
1009 * @param[out] error
1010 * Pointer to rte meter error structure.
1011 *
1012 * @return
1013 * 0 on success, a negative errno value otherwise and rte_errno is set.
1014 */
1015 static int
mlx5_flow_meter_stats_read(struct rte_eth_dev * dev,uint32_t meter_id,struct rte_mtr_stats * stats,uint64_t * stats_mask,int clear,struct rte_mtr_error * error)1016 mlx5_flow_meter_stats_read(struct rte_eth_dev *dev,
1017 uint32_t meter_id,
1018 struct rte_mtr_stats *stats,
1019 uint64_t *stats_mask,
1020 int clear,
1021 struct rte_mtr_error *error)
1022 {
1023 static uint64_t meter2mask[RTE_MTR_DROPPED + 1] = {
1024 RTE_MTR_STATS_N_PKTS_GREEN | RTE_MTR_STATS_N_BYTES_GREEN,
1025 RTE_MTR_STATS_N_PKTS_YELLOW | RTE_MTR_STATS_N_BYTES_YELLOW,
1026 RTE_MTR_STATS_N_PKTS_RED | RTE_MTR_STATS_N_BYTES_RED,
1027 RTE_MTR_STATS_N_PKTS_DROPPED | RTE_MTR_STATS_N_BYTES_DROPPED
1028 };
1029 struct mlx5_priv *priv = dev->data->dev_private;
1030 struct mlx5_flow_meter *fm;
1031 struct mlx5_flow_policer_stats *ps;
1032 uint64_t pkts_dropped = 0;
1033 uint64_t bytes_dropped = 0;
1034 uint64_t pkts;
1035 uint64_t bytes;
1036 int i;
1037 int ret = 0;
1038
1039 if (!priv->mtr_en)
1040 return -rte_mtr_error_set(error, ENOTSUP,
1041 RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL,
1042 "Meter is not supported");
1043 /* Meter object must exist. */
1044 fm = mlx5_flow_meter_find(priv, meter_id);
1045 if (fm == NULL)
1046 return -rte_mtr_error_set(error, ENOENT,
1047 RTE_MTR_ERROR_TYPE_MTR_ID,
1048 NULL, "Meter object id not valid.");
1049 ps = &fm->policer_stats;
1050 *stats_mask = ps->stats_mask;
1051 for (i = 0; i < RTE_MTR_DROPPED; i++) {
1052 if (*stats_mask & meter2mask[i]) {
1053 ret = mlx5_counter_query(dev, ps->cnt[i], clear, &pkts,
1054 &bytes);
1055 if (ret)
1056 goto error;
1057 if (fm->action[i] == MTR_POLICER_ACTION_DROP) {
1058 pkts_dropped += pkts;
1059 bytes_dropped += bytes;
1060 }
1061 /* If need to read the packets, set it. */
1062 if ((1 << i) & (*stats_mask & meter2mask[i]))
1063 stats->n_pkts[i] = pkts;
1064 /* If need to read the bytes, set it. */
1065 if ((1 << (RTE_MTR_DROPPED + 1 + i)) &
1066 (*stats_mask & meter2mask[i]))
1067 stats->n_bytes[i] = bytes;
1068 }
1069 }
1070 /* Dropped packets/bytes are treated differently. */
1071 if (*stats_mask & meter2mask[i]) {
1072 ret = mlx5_counter_query(dev, ps->cnt[i], clear, &pkts,
1073 &bytes);
1074 if (ret)
1075 goto error;
1076 pkts += pkts_dropped;
1077 bytes += bytes_dropped;
1078 /* If need to read the packets, set it. */
1079 if ((*stats_mask & meter2mask[i]) &
1080 RTE_MTR_STATS_N_PKTS_DROPPED)
1081 stats->n_pkts_dropped = pkts;
1082 /* If need to read the bytes, set it. */
1083 if ((*stats_mask & meter2mask[i]) &
1084 RTE_MTR_STATS_N_BYTES_DROPPED)
1085 stats->n_bytes_dropped = bytes;
1086 }
1087 return 0;
1088 error:
1089 return -rte_mtr_error_set(error, ret, RTE_MTR_ERROR_TYPE_STATS, NULL,
1090 "Failed to read policer counters.");
1091 }
1092
1093 static const struct rte_mtr_ops mlx5_flow_mtr_ops = {
1094 .capabilities_get = mlx5_flow_mtr_cap_get,
1095 .meter_profile_add = mlx5_flow_meter_profile_add,
1096 .meter_profile_delete = mlx5_flow_meter_profile_delete,
1097 .create = mlx5_flow_meter_create,
1098 .destroy = mlx5_flow_meter_destroy,
1099 .meter_enable = mlx5_flow_meter_enable,
1100 .meter_disable = mlx5_flow_meter_disable,
1101 .meter_profile_update = mlx5_flow_meter_profile_update,
1102 .meter_dscp_table_update = NULL,
1103 .policer_actions_update = NULL,
1104 .stats_update = mlx5_flow_meter_stats_update,
1105 .stats_read = mlx5_flow_meter_stats_read,
1106 };
1107
1108 /**
1109 * Get meter operations.
1110 *
1111 * @param dev
1112 * Pointer to Ethernet device structure.
1113 * @param arg
1114 * Pointer to set the mtr operations.
1115 *
1116 * @return
1117 * Always 0.
1118 */
1119 int
mlx5_flow_meter_ops_get(struct rte_eth_dev * dev __rte_unused,void * arg)1120 mlx5_flow_meter_ops_get(struct rte_eth_dev *dev __rte_unused, void *arg)
1121 {
1122 *(const struct rte_mtr_ops **)arg = &mlx5_flow_mtr_ops;
1123 return 0;
1124 }
1125
1126 /**
1127 * Find meter by id.
1128 *
1129 * @param priv
1130 * Pointer to mlx5_priv.
1131 * @param meter_id
1132 * Meter id.
1133 *
1134 * @return
1135 * Pointer to the profile found on success, NULL otherwise.
1136 */
1137 struct mlx5_flow_meter *
mlx5_flow_meter_find(struct mlx5_priv * priv,uint32_t meter_id)1138 mlx5_flow_meter_find(struct mlx5_priv *priv, uint32_t meter_id)
1139 {
1140 struct mlx5_flow_meters *fms = &priv->flow_meters;
1141 struct mlx5_flow_meter *fm;
1142
1143 TAILQ_FOREACH(fm, fms, next)
1144 if (meter_id == fm->meter_id)
1145 return fm;
1146 return NULL;
1147 }
1148
1149 /**
1150 * Attach meter to flow.
1151 * Unidirectional Meter creation can only be done
1152 * when flow direction is known, i.e. when calling meter_attach.
1153 *
1154 * @param [in] priv
1155 * Pointer to mlx5 private data.
1156 * @param [in] meter_id
1157 * Flow meter id.
1158 * @param [in] attr
1159 * Pointer to flow attributes.
1160 * @param [out] error
1161 * Pointer to error structure.
1162 *
1163 * @return the flow meter pointer, NULL otherwise.
1164 */
1165 struct mlx5_flow_meter *
mlx5_flow_meter_attach(struct mlx5_priv * priv,uint32_t meter_id,const struct rte_flow_attr * attr,struct rte_flow_error * error)1166 mlx5_flow_meter_attach(struct mlx5_priv *priv, uint32_t meter_id,
1167 const struct rte_flow_attr *attr,
1168 struct rte_flow_error *error)
1169 {
1170 struct mlx5_flow_meter *fm;
1171 int ret = 0;
1172
1173 fm = mlx5_flow_meter_find(priv, meter_id);
1174 if (fm == NULL) {
1175 rte_flow_error_set(error, ENOENT,
1176 RTE_FLOW_ERROR_TYPE_UNSPECIFIED, NULL,
1177 "Meter object id not valid");
1178 return fm;
1179 }
1180 rte_spinlock_lock(&fm->sl);
1181 if (fm->mfts->meter_action) {
1182 if (fm->shared &&
1183 attr->transfer == fm->transfer &&
1184 attr->ingress == fm->ingress &&
1185 attr->egress == fm->egress)
1186 fm->ref_cnt++;
1187 else
1188 ret = -1;
1189 } else {
1190 fm->ingress = attr->ingress;
1191 fm->egress = attr->egress;
1192 fm->transfer = attr->transfer;
1193 fm->ref_cnt = 1;
1194 /* This also creates the meter object. */
1195 fm->mfts->meter_action = mlx5_flow_meter_action_create(priv,
1196 fm);
1197 if (!fm->mfts->meter_action) {
1198 fm->ref_cnt = 0;
1199 fm->ingress = 0;
1200 fm->egress = 0;
1201 fm->transfer = 0;
1202 ret = -1;
1203 DRV_LOG(ERR, "Meter action create failed.");
1204 }
1205 }
1206 rte_spinlock_unlock(&fm->sl);
1207 if (ret)
1208 rte_flow_error_set(error, EINVAL,
1209 RTE_FLOW_ERROR_TYPE_UNSPECIFIED, NULL,
1210 fm->mfts->meter_action ?
1211 "Meter attr not match" :
1212 "Meter action create failed");
1213 return ret ? NULL : fm;
1214 }
1215
1216 /**
1217 * Detach meter from flow.
1218 *
1219 * @param [in] fm
1220 * Pointer to flow meter.
1221 */
1222 void
mlx5_flow_meter_detach(struct mlx5_flow_meter * fm)1223 mlx5_flow_meter_detach(struct mlx5_flow_meter *fm)
1224 {
1225 #ifdef HAVE_MLX5_DR_CREATE_ACTION_FLOW_METER
1226 rte_spinlock_lock(&fm->sl);
1227 MLX5_ASSERT(fm->ref_cnt);
1228 if (--fm->ref_cnt == 0) {
1229 mlx5_glue->destroy_flow_action(fm->mfts->meter_action);
1230 fm->mfts->meter_action = NULL;
1231 fm->ingress = 0;
1232 fm->egress = 0;
1233 fm->transfer = 0;
1234 }
1235 rte_spinlock_unlock(&fm->sl);
1236 #else
1237 (void)fm;
1238 #endif
1239 }
1240
1241 /**
1242 * Flush meter configuration.
1243 *
1244 * @param[in] dev
1245 * Pointer to Ethernet device.
1246 * @param[out] error
1247 * Pointer to rte meter error structure.
1248 *
1249 * @return
1250 * 0 on success, a negative errno value otherwise and rte_errno is set.
1251 */
1252 int
mlx5_flow_meter_flush(struct rte_eth_dev * dev,struct rte_mtr_error * error)1253 mlx5_flow_meter_flush(struct rte_eth_dev *dev, struct rte_mtr_error *error)
1254 {
1255 struct mlx5_priv *priv = dev->data->dev_private;
1256 struct mlx5_flow_meters *fms = &priv->flow_meters;
1257 struct mlx5_mtr_profiles *fmps = &priv->flow_meter_profiles;
1258 struct mlx5_flow_meter_profile *fmp;
1259 struct mlx5_flow_meter *fm;
1260 const struct rte_flow_attr attr = {
1261 .ingress = 1,
1262 .egress = 1,
1263 .transfer = priv->config.dv_esw_en ? 1 : 0,
1264 };
1265 void *tmp;
1266 uint32_t i;
1267
1268 TAILQ_FOREACH_SAFE(fm, fms, next, tmp) {
1269 /* Meter object must not have any owner. */
1270 MLX5_ASSERT(!fm->ref_cnt);
1271 /* Get meter profile. */
1272 fmp = fm->profile;
1273 if (fmp == NULL)
1274 return -rte_mtr_error_set(error, EINVAL,
1275 RTE_MTR_ERROR_TYPE_METER_PROFILE_ID,
1276 NULL, "MTR object meter profile invalid.");
1277 /* Update dependencies. */
1278 fmp->ref_cnt--;
1279 /* Remove from list. */
1280 TAILQ_REMOVE(fms, fm, next);
1281 /* Free policer counters. */
1282 for (i = 0; i < RTE_DIM(fm->policer_stats.cnt); i++)
1283 if (fm->policer_stats.cnt[i])
1284 mlx5_counter_free(dev,
1285 fm->policer_stats.cnt[i]);
1286 /* Free meter flow table. */
1287 mlx5_flow_destroy_policer_rules(dev, fm, &attr);
1288 mlx5_flow_destroy_mtr_tbls(dev, fm->mfts);
1289 mlx5_ipool_free(priv->sh->ipool[MLX5_IPOOL_MTR], fm->idx);
1290 }
1291 TAILQ_FOREACH_SAFE(fmp, fmps, next, tmp) {
1292 /* Check unused. */
1293 MLX5_ASSERT(!fmp->ref_cnt);
1294 /* Remove from list. */
1295 TAILQ_REMOVE(&priv->flow_meter_profiles, fmp, next);
1296 mlx5_free(fmp);
1297 }
1298 return 0;
1299 }
1300