Lines Matching refs:command
60 Hooks called prior to the issue of SET FEATURES - XFER MODE command. The
74 XFER MODE command completes successfully.
107 ATA command execute
115 causes an ATA command, previously loaded with ``->tf_load()``, to be
129 command.
167 Issues the low-level hardware command(s) that causes one of N hardware
227 flag in the DMA command register.
248 ``->qc_issue`` is used to make a command active, once the hardware and S/G
305 after executing a probe-time or EH-time command via
326 command was active (if any), and calls ata_sff_host_intr(ap,qc).
385 In libata, a command is represented with
388 for command executions. Currently only one qc is allocated per port but
402 Once allocated qc's taskfile is initialized for the command to be
435 Currently 6 ATA command protocols are used. They can be sorted into the
451 command. Once BSY is turned off by the device, packet_task
498 needed to acquire sense data. If an ATAPI command fails,
548 about the timed out command and ready for new commands.
551 usual command processing. On EH entrance, the device is not in
608 error condition is reported from device or a command has timed out.
632 during issuing or execution any ATA/ATAPI command.
635 issue a command.
639 - DRQ on command completion.
643 terminate the PACKET command with an error before the last byte of
644 the command packet has been written" in the error outputs description
645 of PACKET command and the state diagram doesn't include such
667 during command execution and on completion.
672 command is not supported and falls in this category.
695 command. Combined with the fact that MWDMA and PIO transfer errors
725 This can be invalid command or parameter indicated by ABRT ERROR bit
747 PACKET command. For this kind of errors, sense data should be acquired
748 to gather information regarding the errors. REQUEST SENSE packet command
760 NCQ command error is indicated by cleared BSY and set ERR bit during NCQ
761 command phase (one or more NCQ commands outstanding). Although STATUS
764 command has failed and acquire more information.
768 command can be handled as a normal ATA command error as in
772 have completed normally if it were not for the failed command.
793 - On some controllers, command timeout. In this case, there may be a
803 encountering repetitive ABRT errors for known supported command is
824 the timed out command has completed successfully or with error. This is
831 This is when timeout occurs and the command is still processing or the
834 it forget about the timed out command, resetting is necessary. The timed
835 out command may be retried.
904 EXECUTE DEVICE DIAGNOSTIC command
907 Host-side EDD protocol can be handled with normal command processing
916 ATAPI DEVICE RESET command